Viewing coordinate data
To show the coordinate data records in a list, press
[2] in
the Data menu.
The newest record is at the bottom of the screen.
To scroll through the records, press
[^] or [v]. To move up
or down one page, press
[<] or [>].
Press
[ENT] to see more detailed information about the
selected record.
The header (XYZ, YXZ, NEZ, or ENZ) depends on the Coord. Label setting in
[MENU] / Settings / Coord. See also Coordinate, page 99.
UP, MP, CC, and RE records
All coordinate records contain PT, CD, X, Y, and Z fields.
• UP records are uploaded point coordinates.
• MP records are manually input point coordinates.
• CC records are points calculated in Cogo.
• RE records are points calculated in Base Line and Resection station setup.
Deleting records
Deleting raw records
1. In the RAW screen, use
[^] or [v] to highlight the
record that you want to delete. Then select the
DEL softkey.
2. A confirmation screen appears.
a. To delete the selected record, press
[ENT] or
select the
Yes softkey.
b. To cancel the deletion of data, press
[ESC] or
select the
No softkey.