User's Manual

5 Menu Screen
108 Spectra Precision Focus 4 Total Station User Guide
4. Do one of the following:
To accept the changes and return to the
data view screen, press
[ENT] or select the
Yes softkey.
To return to the Edit screen, press [ESC] or
select the
No softkey.
Editing station records
Note – The system will not recalculate measurements if you change the station record. You
will need to recalculate all coordinate and raw data that was collected from an edited
station record in your postprocessing software.
1. In the RAW screen, use
[^] or [v] to highlight the
station record to edit. Then select the
Edit
softkey.
2. Use
[^] or [v] to highlight a field. Then modify the
value in the selected field. You can edit any field
in the ST record, but the instrument does not
recalculate the measurements from this station.
3. To finish editing, press
[ENT] in the AZ field.
If you change the ST and HI values, the
coordinates of observation points are not recalculated. A comment record is
stored to record the change. The following is a comment record for a changed HI
value:
CO, HI changed at ST:9012 Old HI = 1.3456m
If you change the BS or AZ values, raw records are not recalculated. A comment
record is stored to record the change.