User's Manual

3 Getting Started
52 Spectra Precision Focus 4 Total Station User Guide
Entering a point by recording an instant measurement
1. Press the
MsrPT softkey:
An observation screen appears.
2. To start a measurement, press
[MSR1] or [MSR2].
3. To change the height of the target, select the
HT
softkey.
4. When you have finished the measurement, press
[ENT] to go to the point recording
screen.
5. Enter the point or code name and then press
[ENT].
When you move the cursor to a field, the current or
default value appears in inverted colors. (It appears as
white text on a black background). This is the default
Replace All input mode.
To change the input mode to Overwrite and highlight
the first character, press
[>]. To move the cursor to the
end of the string, press
[<].
Entering a point from the point stack
The point stack is a list of the last 20 point names used,
in chronological order from last used to first used. To
enter a point from the point stack:
1. Select the
Stack softkey when the cursor is in
the PT field. The stack appears.
2. Press
[^] or [v] to move the cursor to the point that you want to use.
3. Press
[ENT].
When you return to the point input screen, the selected
point name is entered in the PT field, incremented by
one. For example, if you selected the A101 point, A102
appears in the PT field.