User's Manual

4 Applications
60 Spectra Precision Focus 4 Total Station User Guide
HA reset and angle operations
To access the Angle menu, press [ANG] in the Basic
Measurement Screen (BMS). To select a command from
the Angle menu, press the corresponding number key.
Alternatively, press
[^] or [v] to highlight the command
and then press
[ENT].
Setting the horizontal angle to 0
Press [1] or select 0-Set in the Angle menu. The display returns to the BMS.
Entering the horizontal angle
1. Press [2] or select Input in the Angle menu. The
HA Input screen appears.
2. Use the numeric keys to enter the horizontal
angle.
3. Press
[ENT].
To enter 123°45'50", key in
[1] [2] [3] [.] [4] [5] [5] [0].
The displayed value is rounded to the minimum angle increment.
Station setup
To access the Stn Setup menu, press [STN] in the BMS.
To select a command from the Stn Setup menu, press
the corresponding number key. Alternatively, press
[^] or
[v] to highlight the command and then press [ENT].
The last function used is highlighted.
The station setup options are:
Baseline, page 61
Known, page 62
Resection, page 64
Base XYZ, page 67
Remote BM, page 68
BS Check, page 69