User's Manual

Spectra Precision Focus 4 Total Station User Guide 63
Applications 4
Sighting the backsight by entering coordinates
1. To enter coordinates for the backsight point (BS),
press
[1] or select Coord from the Backsight
screen.
2. Enter the point name. If the point exists in the
job, its coordinates are shown.
3. If you intend to take a distance measurement to the BS, enter the height of
target in the HT field.
4. Sight the BS, and then press
[ENT] to complete the setup.
If measuring to a known coordinate BS, press
[DSP] to display a QA screen. The QA screen shows
the dHD and dVD values, which indicate the
difference between the measured distance and
the distance calculated from the known
coordinates.
5. To record the station, press
[ENT].
6. To finish the station setup after taking a distance measurement, press
[ENT].
HA Azimuth calculated by
coordinates
Z
Y
X0
X
Xb
Y0 Yb
Backsight point
(Xb, Yb, Zb)
Station point
(Xi, Yi, Zi)
Instrument height