Contents 1. Overview 1.1 Features 1.2 Operating Environment 2. Before Operation 2.1 Inspection 2.2 Accessories 2.3 Options 2.4 Notes on Use 2.5 Cleaning the Unit 35mm Film Scanner LS-1000 3. Parts Identification 3.1 Main Unit 3.2 Display LED 3.3 Strip Film Holder FH-2 4. Connecting the LS-1000 4.1 Before Connection 4.2 Connecting the Power Cord 4.3 Connecting the SCSI Cable 4.4 Setting the SCSI ID 5. Operation 5.1 Turning on the Power 5.2 Film Insertion User’s Manual 6.
Cautions Indication • The reproduction of all or part of this manual without our permission is prohibited. • The information contained in this manual is subject to change without notice. • We have made every effort to produce a perfect manual, but should you find any mistakes, we would be grateful if you would kindly let us know. • We shall take no responsibility for consequences resulting from the operation of this product, despite the terms mentioned above.
Federal Communications Commission (FCC) Radio Frequency Interference Statement CAUTIONS installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Cautions for Safety In order to use the LS-1000 safely and correctly, and to prevent problems, pay careful attention to the following points: • Be sure that the electrical outlet of the power supply is grounded. Conduct the grounding in common to the other machines it is being connected with. Unless common grounding is conducted, ground loop will occur, which will cause electric shock and noise static. • Use an AC power supply of 50/60Hz and a voltage of from 100V–240V.
• Do not pull or bent the SCSI cable. This can cause the cable to break. • Do not insert any foreign objects inside the unit. If flammable objects, metal, or water come in contact with the interior of the unit, failure, fire, and/or an electrical shock may result. • Do not connect or remove peripheral equipment while the power switch is on. • Do not unplug the power cord while the power switch is on. • Do not move the Unit while the power switch is on. • On no account disassemble the Unit.
If You Notice Anything Abnormal Storage and Operating Locations If unusual noise, odor or smoke occurs, switch the Unit off Proper storage will ensure the long life of the Unit. In order to immediately and disconnect the power cord and the SCSI cable. avoid internal dust while being stored, it is recommended that Contact your retailer or Nikon sales representative in your an appropriate cover be used on the Unit. country.
• The Unit is exposed to direct sunlight. • The Unit may be subjected to excessive vibration or physical shocks. • The atmosphere is excessively dusty.
• The Unit is exposed to noise from other equipment nearby. When Taking the Unit Out of The Country The use of this product may violate local laws and restrictions in some countries. If this is the case, we cannot bear any responsibility for any violations resulting from the use of this product. Leave suffucient space around the unit to ensure that the ventilation slots are not blocked. Blocking these slots may cause an internal heat build-up. Place the unit on a level and stable surface for operation.
Notice concerning prohibition of copying or reproduction • Cautions on certain copies and reproductions The government has issued cautions on copies or reproductions of securities issued by private companies (shares, bills, checks, gift certificates, etc.), commuter passes, or coupon tickets, except when a minimum of necessary copies are to be provided for business use by a company.
1. Overview 1.1 Features Thank you for purchasing the Nikon 35mm Film Scanner LS-1000. This manual describes the procedures for unpacking, setting up, and connecting the scanner, with emphasis on hardware use and cautions. The LS-1000 is a film scanner capable of scanning 35mm film (color/monochrome, negative/positive) at high speed and high resolution. Please read this manual thoroughly to ensure proper operation of your scanner.
➤ Leave extra space around and above the unit to ensure smooth operation. Please refer to the drawing below for the amount of space to be provided. ➤ ➤ In the case of horizontal installation 1.2 Operating Environment 4inches (10cm) If possible, place a suitable cover over the unit to avoid dust accumulating when it is stored. ➤ ➤ 4inches (10cm) 23.6inches (60cm) ➤ 2inches (5cm) ➤ ➤ ➤ ➤ 23.
2. Before Operation 2.1 Inspection Power cord (1) * The shape of the plug depends on the country of use. Inspect the package to see whether any damage has occurred during shipment. If there is any damage to the package, please contact our retailer directly and do not unpack the unit. SCSI cable (1) (50pin full pitch Dsub 25pin) 2.2 Accessories The following items are included with your LS-1000. When you open the package, check whether all the items are present.
2.3 Options 2.4 Notes on Use The LS-1000 has an optional auto slide feeder, the SF-100, which enables automatic feeding of mounted 35mm slides. • Don’t use a slide mount neither less than 1.1mm nor more than 3.0mm thick. If the slide mount is not flat on its surface, you may feel some roughness when mounting or unmounting the slide. • Don’t force the slide-mount or strip film holder into or out of the unit if it does not move smoothly.
2.5 Cleaning the Unit When carrying out routine maintenance and cleaning, ensure that no volatile liquids such as alcohol, benzine, or thinner come into contact with the LS-1000 as this may cause a failure, fire, or electric shock. Please observe the following points: • Before cleaning, always turn the power off, and pull out the power plug. • Since the front cover is made from plastic material, remove dust with a blower or a dry cloth.
3. Parts Identification Film Loading Slot: The film holder is inserted here. 3.1 Main Unit Option Connector: The SF-100 slide autofeeder is connected to this option connector. Front panel Status Display LED: Shows the scanner status. Ventilation Holes Power Switch: Power Switch Directly turns the AC power on/off. Ventilation Holes: Since air is drawn in through these holes, make sure that they are not blocked by other equipment.
Rear panel SCSI Connector: For SCSI cable connection. (No difference between IN and OUT.) SCSI ID Switch: Sets the SCSI ID number. Numbers 0 to 7 are shown and valid. AC Inlet: AC Inlet SCSI Connector 5 SCSI ID switch - 16 - Connect to the AC power source with the power cord provided.
3.2 Display LED The display LED is located on the front panel and shows the scanner status. Steady illumination: Lights when power is supplied (READY status). Blinking (about once every 1.5 seconds): Blinks slowly during operation (BUSY status). Also blinks when the power is switched on and during initialization. Fast blinking (about 5 times a second): Blinks fast when an error occurs either in the LS-1000 or in communication (ERROR status).
3.3 Strip Film Holder FH-2 This strip film holder can be used with a strip of film containing up to six images.
4. Connecting the LS-1000 For an IBM PC/AT or compatible in which an SCSI board has not been installed, install an SCSI board as explained in the manual supplied with the board. 4.1 When installing an SCSI board for the first time, be careful not to use the same number as used for another purpose such as an I/O address, interrupt number, or graphic board DMA channel. Before Connection Before connecting the cables, confirm that all devices, including the computer system and the LS-1000, are turned off.
4.2 Connecting the Power Cord • Before connecting the power cord, confirm that the unit’s power switch is in the off position. Insert the female end of the supplied power cord into the AC inlet located on the rear panel, then insert the plug into the AC power outlet. The power source must be grounded. • If possible, try to use an independent electric outlet.
4.3 Connecting the SCSI Cable Before connecting the SCSI cable, confirm that all SCSI devices, including the computer system, have been turned off. Connect the unit to the computer using the SCSI cable. After attaching the connector, be sure to lock it in place. You can connect the SCSI cable to either of the SCSI connectors on the rear panel of the unit.
If the unit is the only connected SCSI device, or if the unit is connected at the end of the SCSI chain, attach a terminator (terminal resistance) to the other SCSI connector. At this point, remove the terminator of the other SCSI device that has been placed between them. The terminator is not needed when the unit is connected between other SCSI devices. When SCSI devices are connected, connect them so as not to make a loop, and attach terminators to both ends of the SCSI chain.
SCSI Chain Connection with Other Devices If LS-1000 is connected between the other SCSI devices; If the LS-1000 is connected at the end of the SCSI chain; • Connect the 50-pin full pitch connector of the SCSI cable to the SCSI connector located on the rear panel of the Unit, and insert the other end to the SCSI connector of other SCSI device. • Connect the supplied terminator (terminal resistance) to the other SCSI connector on the rear panel of the Unit.
Remarks • The maximum number of SCSI devices that can be connected to one computer is eight. In the case of a host computer with a built-in SCSI hard disk or built-in CD-ROM, note that SCSI ID numbers have been pre-assigned for the host CPU and the SCSI devices. • Before installing an SCSI board, be sure to read the user’s manual provided with the board. The numbers for the I/O address, interrupt level (INT) and DMA channel might be used for other interface boards and peripheral devices.
Remarks 4.4 Setting the SCSI ID • To change the ID, confirm that the LS-1000 power is off. The ID cannot be changed when the power is on. The SCSI ID for the LS-1000 is set at “5” when the unit is shipped. If other SCSI devices are connected to your computer, make sure that the SCSI ID for the LS-1000 is different from those assigned to other SCSI devices.
Remarks 5. Operation 5.1 Turning on the Power • To turn the LS-1000 power off, turn the host computer off first, the other SCSI devices next, and the LS-1000 last (reverse order from switching on). Turn the LS-1000 on first, the other SCSI devices next, and the host computer last. • Once the power is turned off, please wait five seconds or more before turning the power on again. After turning the power on, the LED will begin to blink to indicate scanner initialization.
Insert the mounted slide lengthways until it touches the back inner wall. 5.2 Film Insertion The LS-1000 can scan different types of 35mm positive/negative monochrome/color images. In addition, it can scan a film strip of up to 6 images or single mounted film. Insertion of Mounted slides The LS-1000 can scan mounted slides as they are. • Confirm that the thickness of the mounted slides to be scanned is between 1.1mm and 3.0mm. • Ensure that the emulsion surface is facing in the proper direction.
The standard orientation of a mounted portrait or landscape slide is shown below. (If the top and bottom are reversed, modification is possible by using the software.
Insertion of Strip film Step 2 Insert the strip film into the attached film holder FH-2, and then insert the holder into the film slot of the front panel of the Unit. Place the strip film on the concave section which is fixed in the adaptor of the lower holder. Be sure to place the strip film so that the emulsion surface will be facing down (the shiny surface will be facing up). The direction is correct if the image number can be read. Step 1 Remove the adaptor snap and open the upper holder.
Step 3 Step 4 Align each image of the strip film with an aperture in the lower holder. Close the upper holder, aligning both ends of the upper holder and the lower holder. Fasten the snaps at both ends of the holder after securing the adaptor cover and fastening the adaptor's snap.
Step 5 Align the image to be read with either of the two apertures in the silver-colored adaptor. Insert the film holder in the film slot of the front panel in the LS1000, with placing the aperture through which the image is to be read toward the slot. The first image will be read. The film holder can be inserted into the LS-1000 from either end. Decide the insertion direction of the film holder according to which image is to be read. The second image will be read. The third image will be read.
Step 6 Remarks: Insert the film holder until it touches the back inside wall of the unit and the mark comes in alignment with the edge of film slot. • Do not forcefully insert the film holder. • Though the film holder is made of plastic, it will be damaged if film is forced into it. • Remove dust on the film or film holder with a blower or photographic brush.
• Have you installed software? For information on installing and operating software, refer to the software manual provided with the unit. 6. Troubleshooting If something unusual should occur, please check the following items before you assume that there is a unit failure. For more details, refer to the Troubleshooting section of the software manual. • Have you properly set the configuration, such as CONFIG.
Output data: Full color (8 bits/color) Focus: Auto-focus Film holder: Not required for mounted slide scanning. FH-2 is used for strip film scanning. Interface: SCSI-2 compliant Size: Scanning method: Stepper-driven film stage, single pass method 6.0 (W) x 10.5 (H) x 2.5 (D) inches (151 x 267.5 x 63.3mm) Weight: Approx. 4.2lbs (1.9kg) Sensor: 2,592 pixel linear CCD image sensor Power supply: Light source: RGB LED Array AC 100 - 120V/AC 200 - 240V, 50/60Hz, 0.80 - 0.
Index A AC inlet 16 Accessories 12 C Connecting 19–25 connecting the SCSI cable 21 connecting the terminator 22 preparation for 19 to other devices in an SCSI chain 23 F FH-2 12, 18 adaptor snap 18 holder snap 18 Film inserting 27–34 Film slot 15 Film strips inserting 29–34 I Installation horizontal 11 vertical 11 L O Operating environment 11 Option connector 15 P Power cord, connecting 20 Power switch 15 S SCSI cable 12, 21, 22 SCSI connector 16 SCSI ID 25 SCSI ID switch 16 SF-100 auto slide feeder
EC DECLARATION OF CONFORMITY ERKLÄRUNG ÜBER EG-NORMENGERECHTHEIT We Name: Address: Wir Name: Anschrift: Nikon UK Limited Nikon House, 380 Richmond Road, Kingston, Surrey KT2 5PR, UK declare that the product Product Name: Product Option: Manufacturer’s Name: Manufacturer’s Address: Nikon 35mm Film Scanner LS-1000 Auto Slide Feeder SF-100 Nikon Corporation Fuji Bldg.