User's Manual
En_03
192
l
A Using FV Lock with the Built-in Flash
FV lock is only available with the built-in flash when TTL is selected for 
Custom Setting e3 (Flash cntrl for built-in flash, 0 301).
A Using FV Lock with Optional Flash Units
FV lock is also available with optional flash units in TTL and (where 
supported) monitor pre-flash AA and monitor pre-flash A flash control 
modes. Note that when commander mode is selected for Custom 
Setting e3 (Flash cntrl for built-in flash, 0 301), you will need to set 
the flash control mode for the master or at least one remote group to 
TTL or AA.
A Metering
The metering areas for FV lock when using optional flash unit are as 
follows:
Flash unit Flash mode Metered area
Stand-alone flash unit
i-TTL 6-mm circle in center of frame
AA
Area metered by flash exposure 
meter
Used with other flash 
units (Advanced 
Wireless Lighting)
i-TTL Entire frame
AA 
Area metered by flash exposure 
meter
A (master 
flash)
A See Also
For information on using the depth-of-field preview button or A AE-L/
AF-L button for FV lock, see Custom Setting f5 (Assign preview button, 
0 315) or Custom Setting f6 (Assign AE-L/AF-L button, 0 315).