Product Manual
Table Of Contents
- Nikon N Series/K Series Total Station Instruction Manual
- Legal Notices
- Safety
- Introduction
- Preparation
- Unpacking and Packing the Instrument
- Charging the Battery Pack
- Detaching and Re-Attaching the Battery Pack
- Setting Up the Tripod
- Centering
- Leveling
- Sighting
- Setting the Measurement Mode and Preparing the Target
- Measurement in Reflectorless Mode (N 2" and N 5" only)
- Setting Up the Prism Reflector
- Face-1/Face-2 Measurement
- External Device Connector
- Getting Started
- Applications
- HA Reset and Angle Operations
- Station Setup
- Setting up a station with known coordinates or azimuth
- Setting up a station using multiple point resection
- Setting up the station quickly without coordinates
- Determining station elevation
- Checking and resetting the backsight direction
- Base XYZ function
- Two-point resection along a known line
- Setting up a station for traverse measurement
- Use last
- Stakeout
- Program Key
- Recording Measurement Data
- Measuring Offsets
- Menu Key
- Checking and Adjustment
- System Diagrams
- Communications
- Error Messages
Safety
x Nikon N Series/K Series Total Station Instruction Manual
Table 1.1 Specifications for laser emission
Laser Pointer Class 2 (only N 2" and N 5")
Wave length 630-680 nm
Output power cw Po ≤ 1 mW
Disatance Meter
Wave length 850-890 nm
Output power Pulse Po ≤ 6.4 W
Pulse width < 5 ns
Table 1.2 Conforming standards
E.U. IEC 60825-1:2014
Laser Pointer: Class 2 (only N 2" and N 5")
Distance Meter: Class 1
USA FDA21CFR Part 1040 Sec.1040.10 and 1040.11
(except for deviations pursuant to Laser Notice No.50, dated June
24, 2007)
Laser Radiation Label
for N 2" and N 5"
Laser Radiation Label
for K 2" and K 5"
CFR Label
FCC Label
EAC label