Operation Manual

52
Jp
En
Fr
Es
Pt
53
Jp
En
Fr
Es
Pt
Operation and internal display
5 Height mode
8
Power off
Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without
operation
Operation/Results Work Button Display
Display examples
meter yards
Elevation (°) Depression (°)
5 Measurement with height mode
5-1 Seeking your target
Height (from horizontal)
(Align the reticle with target)
5-2 Measurement
With the POWER button depressed,
POWER
(Laser irradiate symbol is displayed.)
continuous measurement is possible for up to
20 seconds. (When done, 5-3 display appear)
5-3 Failure to measure Repeat step 5-1.
5-4
Measurement OK
Height (from horizontal)
45.0 49.2
Follow by 5-5 or 5-1.
5-5 Data display after (1) Anglefrom horizontal)【 6 MODE
13 -13
switching modes
(2) Vertical separation MODE
blinks
(height between two points)7
(3) Linear distance3 MODE
206 225
(4) Horizontal distance4 MODE 201 220
(5) Height (from horizontal) MODE 45.0 49.2
Return to 5-5-(1) and repeat.
MODE
(In Limited mode, return to 5-5-(3),
then repeat (3), (4) and (5).
Switching the measurement unit
changes it for each mode. The POWER
button can be used to measure in each
mode. See the relevant section.
The angle and vertical separation
(height between two points) are
displayed when set at FULL mode.
Limited mode shows linear distance,
horizontal distance and height.
6 Angle mode
8
Power off
Regardless of process, after 30 seconds 30 seconds
since your last operation, power turns off. without
operation
Operation/Results Work Button Display
Display examples
meter yardst
Elevation (°) Depression (°)
6   Measurement with angle mode setting (only at FULL mode setting)
6-1 Seeking your target Angle (from horizontal)
(Align the reticle with target.)
6-2 Measurement With the POWER button depressed,
(Laser irradiate symbol is displayed.) continuous measurement is possible
POWER
for up to 20 seconds.
(When done 6-3 display appears)
6-3 Failure to measure Repeat step 6-1.
6-4 Measurement OK Angle (from horizontal) 13 -13
Follow by 6-5 or 6-1. 5.2 -5.2
6-5 Data display after (1) Vertical separation between MODE
blinks
switching modes two points7
(2) Linear distance3 MODE
206 225
(3) Horizontal distance4 MODE 201 220
(4) Height (from horizontal)5 MODE 45.0 49.2
(5) Angle (from horizontal) MODE 13 -13
Return to 6-5-(1), then repeat.
Switching the measurement unit
changes it for each mode. The
POWER button can be used to
measure in each mode
See the relevant section.