_ NILES® 0 INSTALLATION & OPERATION 0 0 0 GUIDE flUSH-MOUNT IR MICROSENSOR® 0
INTRODUCTION FEATURES & BENEFITS The MS120 is aflush-mount IR sensor designed for use with the Niles infrared extender systems. The MS120 offers a number of improvements over other miniature IR sensors.
INSTALLATION CONSIDERATIONS Type of Cable The MS120 connects to the Niles infrared main systems unit or IRH61 0 sensor expansion hub with an individual home run of CAT-5 cable. When running wires inside walls, most states and municipalities in the U.S. specify that you must use a special type of wire. Usually, the requirement is that the wire has a specific "CL" fire rating, such as "CL-2" or "CL-3".
We do not recommend this. The cable connected to the MS120 can act as an "antenna" for electrical noise. Locating the MS120 cable too close to a light dimmer or switch may interfere with the MS120. If you must locate the MS120 near electrical devices, install it in a separate metal electrical box, ground the box to the electrical system ground, and route the MS120 cable several feet away from all electrical wiring.
Stereo Receiver Niles IR Flasher 12V DC Power Supply (Supplied with the MSU250 Main System Unit) Plugged into an Unswitched AC Outlet Powers the System + IN DC FLASHU: OUTPUTS 6 f1NILES MSU2S0 I. MAJN nSTlM UNIT HI~ LOW o 12V DC Power supply (Not Supplied) plugged into a switched outlet (Niles stock# FG01 035) '-HI U- LOW MSU250 Power, IR data, status signal and ground via CAT-5 wire MS120 IR Sensor Figure 3.
INSTALLATION If you are installing the MS120 into an existing wall, take time to consider any possible obstructions which may be hidden inside the wall, such as wood or metal studs; electrical, telephone or other types of wiring; plumbing; AC or heating conduits; old wall safes; etc. 1. Determine a mounting location for the MS120. Select a location where you will have access to the rear of the MS120 after it is installed.
TROUBLESHOOTING This manual contains instructions for the MS120 only. For specific information on the adjustment and operation of your Niles infrared extender system, please refer to the instruction manual included with your Niles IR main system unit (MSU140, MSU250, MSU480 MSU440Z). ,. Test the remote control(s) by operating the AN equipment directly. Replace the batteries if needed. 2. Double check the cable connections on the MS120 and on the main system unit. Look for open, shorted or reversed wires. 3.
SPECIFICATIONS IR System Compatible with virtually all brands of remotes using carrier frequencies between 25kHz and 90kHz IR Receiving Range Varies depending on remote strength; 1 typically 20 to-35 (6.10 meters to 10.68 meters) 1 IR Receiving Angle 30 0 off-axis (horizontal and vertical) at 25 (7.62 meters) 1 Mounting 11 Thru-hole, fits into a 1/2 (1.27 cm) diameter hole; requires a minimum of 2-7/8 (7.
LIMITED WARRANTY NILES AUDIO CORPORATION C'NILES") WARRANTS ITS ACTIVE PRODUCTS (THOSE NOT REQUIRING AC OR BATTERY POWER) TO THE ORIGINAL PURCHASER TO BE FREE OF MANUFACTURING DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF PURCHASE. THIS WARRANTY IS SUBJECT TO THE FOLLOWING ADDITIONAL CONDITIONS AND LIMITATIONS.