I N S TA L L AT I O N G U I D E TABLETOP IR SENSOR TS120
CONGRATULATIONS! Thank you for choosing the TS120 Tabletop Infrared Remote Sensor from Niles. With proper installation and operation, you should enjoy years of trouble-free use. Niles manufactures the industry’s most complete line of custom installation components and accessories for audio/video systems. To see the complete Niles product assortment, visit us on the internet at: www.nilesaudio.com.
Introduction The Niles TS120 is a tabletop infrared sensor designed for use with the Niles infrared extender systems. Installed in a remote room location, the TS120 receives the IR commands transmitted from your hand-held remote(s). The IR commands are carried via a CAT-5 cable to your A/V equipment in another room, and instantly “repeated”. The TS120 represents one of the 3 building blocks necessary to complete a Niles IR repeating system: • IR Main System Unit—Models MSU140, MSU250, MSU480 and MSU440Z.
FEATURES AND BENEFITS The TS120 offers a number of improvements over other tabletop IR sensors.
INSTALLATION CONSIDERATIONS Type of Cable The TS120 connects to the Niles infrared main system unit or IRH610 sensor expansion hub with an individual home run of CAT-5 cable. When running wires inside walls, most states and municipalities in the U.S. specify that you must use a special type of wire. Usually, the requirement is that the wire has a specific “CL” fire rating, such as “CL-2” or “CL-3”.
Installation Considerations (continued) Receiving Range and Pickup Angle The receiving range of the TS120 will vary according to the IR output strength of the remote control being used. Remote strength varies among brands depending on the number and size of batteries used, and how many IR emitters the remote has. For example, remotes that operate on two small AAA batteries and have only one IR emitter are generally not as strong as remotes that use the larger AA size batteries and have two emitters.
Installation Considerations (continued) Avoiding Interference TS120 is designed to work in most applications including with plasma and LCD TV’s and in areas where CFL lighting and indirect sunlight are present. You should avoid locating the TS120 near potential sources of electrical or optical noise, such as light dimmers or low-voltage lights.
Installation Considerations 12V DC power supply (supplied with the MSU250 IR main system unit) plugged into an unswitched AC outlet powers the system Bi-colored LED Removable Connector Pins (continued) Niles IR flasher Stereo receiver MSU250 12V DC power supply (not supplied, Niles stock # FG01035) plugged into the switched outlet Power, IR data, and power status signal via CAT-5 wire TS120 IR sensor Figure 1 Parts guide 6 Figure 2 Connecting the TS120 to a Niles MSU250 IR main system unit broadc
Installation Step by Step 1. The TS120 is a small free-standing box designed to sit on a shelf or other convenient surface. The unit can be mounted under a shelf using double-sided tape or Velcro® (not supplied). 2. Run the cable to the TS120. Label the cable for future reference. 3. Locate the connector on the TS120 and remove it. 4. Next, strip 1/4” of insulation from the end of each wire. Tightly twist the end of each wire until there are no frayed ends. 5.
Installation (continued) 6. Insert each wire into the appropriate hole on the removable connector plug (Figure 6), and snap the locking tab down. To help you, the connector plug is keyed. Insert the smooth side of the connector plug into the smooth side of the socket. Don’t force the scalloped side of the connector plug into the smooth side of the socket (Figure 5). 7. Double-check all connections. Plug the connector back into its socket on the TS120.
Operation Operation of the TS120 is simple. Stand within the operational range of your TS120, aim your hand-held remote at the TS120 and press the button for the desired command. Your IR command is instantly repeated to your A/V equipment. Green “Power Status” LED When the TS120 is correctly connected (Figure 2), the Green LED will stay lit as long as the preamp/receiver is on. When your preamp/receiver is off, the LED will stay off.
TROUBLESHOOTING This manual contains instructions for the TS120 only. For specific information on the adjustment and operation of your Niles infrared extender system, please refer to the instruction manual included with your Niles IR Main System Unit (MSU140, MSU250, MSU480, MSU440Z). The bi-color blue/green LED on the front of the TS120 is a useful troubleshooting aid. The blue LED should light only when a remote command is being received.
TROUBLESHOOTING (continued) Eliminating Optical feedback In some installations, two conditions combine to create an optical feedback loop. Symptoms can include poor range, intermittent operation or no operation. The conditions which sometimes combine to create a feedback loop are: 1. Both a sensor and a flasher are located within the same room. 2. There is some low-level noise or interference on your system.
TROUBLESHOOTING (continued) IR Test LED Off: Optical Interference IR Test LED On or Flickering: Electromagnetic and/or Optical Interference EMI (Electromagnetic Interference) Identify the source of the interference. The most common sources of electromagnetic interference are listed in the Installation Considerations section. To eliminate EMI try the following methods: 1. Move the sensor or the sensor cable away from the EMI source or move the source of the EMI away from the sensor or the cable. 2.
Specifications IR System Compatible with virtually all brands of remotes using carrier frequencies between 25kHz and 90kHz IR Receiving Range 20’ to 35’ depending upon the strength of the remote control IR Receiving Angle 30° off-axis (horizontal and vertical) at 25’ Mounting Tabletop Wiring Requirements Individual “home-runs” of CAT-5 cable Unit Dimensions 2-7/8” wide x 1-1/16” high x 3-1/8” deep NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 1-305-238-4373 13
NOTES 14
NOTES NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 1-305-238-4373 15
Limited Warranty Niles Audio Corporation (“NILES”) warrants its active products (those requiring AC or battery power) to the original purchaser to be free of manufacturing defects in material and workmanship for a period of two years from date of purchase. This Warranty is subject to the following additional conditions and limitations.
Detach here and return to: Niles Audio Corporation Warranty Registration Dept. P.O. Box 160818 Miami, Florida 33116-0818 Warranty Registration Card TS120 Model Purchased___________________________________ Serial Number_ __________________________ Date Purchased (month/day/year)_______________________ Dealer Name and Location_ _________________ ❍ Dr. ❍ Miss ❍ Mr. ❍ Mrs. ❍ Ms.
Blending High Fidelity And Architecture® Niles Audio Corporation 1 2 3 3 1 S . W. 1 3 0 S t r e e t M i a m i , F l o r i d a 3 3 1 8 6 3 0 5 - 2 3 8 - 4 3 7 3 • 1 - 8 0 0 - B u y- H i f i – w w w. n i l e s a u d i o . c o m ©2 0 0 9 N i l e s A udi o Corporation. All rights reser ved. Niles, the Niles logos, Inte l l i P a d , M i cr o Fl a s h e r a n d Blending High Fidelity and Architecture are registered trademarks of Niles A u d i o C o r p o r a t i o n .