deutsch svenska english italiano dansk 823 0060 020 Betriebsanleitung ........................................2-15 Bruksanvisning ..................................... 2, 16-28 Operating Instructions .......................... 2, 29-41 Instrucciones de uso ............................ 2, 42-54 Brugsanvisning .....................................
Contents 1. Important safety precautions............................................................................................... 30 1.1 Technical data ........................................................................................................................................30 2. Vacuum unit Centix 20 assembly instructions .......................................................... 31 2.1 Fitting the mounting bracket ........................................................................
1 Important safety precautions • Do not vacuum up sharp objects such as broken glass or needles that could puncture the bag. • Be particularly careful not to pick up objects that could block the hose/pipe system, such as pencils, toy bricks and small plastic bags. • Follow the operating instructions carefully. Servicing and repairs should only be carried out by an authorised workshop. Use only original parts and accessories as recommended by the supplier. Never attempt to modify the machine yourself.
2 Vacuum unit Centix 20 assembly instructions Fig. 1 2.1 Fitting the mounting bracket Position the holder so that there is plenty of space above and below the place where the vacuum unit is to be located. Make sure there is a minimum of 500 mm free space above the Centix 20 container. Mark the positions for the four screw holes with a pen or similar. Then select appropriate screws and, if necessary, wall plugs for the type of wall surface to which the bracket is to be attached.
3 Operating instructions Centix 20 2 1 Fig. 9 Fig. 7 Filter 3.2 Servicing Always unplug the power cord before doing any service work! 3.1 Starting the machine The control current outlet (low voltage) should be connected to a control current lead running the length of the pipes. If suction is poor, it indicates that the flow of air through the machine is restricted. This may be due to the following: Both ends of the low-voltage lead should be connected to the connection panel on the vacuum cleaner.
4 Filter and dust bags - Centix 20 Fig. 12 Fig. 10 4.1 Replacing the dust bag 4.2 Replacing / Cleaning the filter The central vacuum cleaner is fitted with a paper dust bag as standard; never vacuum without a dust bag installed. Grasp the edge of the lid and pull upwards to open it, Fig. 10. Open the lid and take out the dust bag as described earlier. The filter sits at the bottom of the container around the motor housing. Never use the central vacuum cleaner without a filter installed.
5 Vacuum unit Centix 40 / Centix 50 Premium assembly instructions 5.1 Fitting the mounting bracket Plan the positioning of the mounting bracket so that there is plenty of space above and below the area where the vacuum unit is to be located. Make sure there is a minimum of 400 mm free space below the dust container. Mark the positions for all four screw holes with a pen or similar. The diameter of the holes in the holder is 5 mm.
6 Operating instructions Centix 40 / Centix 50 Premium 6.1 Starting the machine 6.3 Centix 50 Premium Display The control current outlet (low voltage) is connected to a control current lead running the length of the pipes. Both ends of the low-voltage lead should be connected to the connection panel on the vacuum unit. One lead to each outlet. The Centix 50 Premium model has a display giving information about the machine, Fig. 19. The display is illuminated and lights up on start-up.
7 Filter and dust bags - Centix 40 / Centix 50 Premium Fig. 22 Fig. 21 Fig. 20 7.1 Replacing the bag filter 7.2 Fitting the bag filter A bag filter must always be installed in the dust container. Clean the filter in the following way: 1. Start by pulling the pipe socket out of the dust container. 2. Release the two handles clamping the dust container. Free them by pulling the handles outwards away from the container, Fig 20. 3. Do not remove the filter from the container.
8 Electrical connection On/Off Outlet for the low-voltage leads: The control current outlet (low voltage) is connected to a control current lead running the length of the pipes. Both ends of the low-voltage lead are connected to the connection panel on the vacuum unit. One lead to each outlet. The low-voltage lead should be connected as illustrated below. Centix 20 Centix 40 Centix 50 Premium The connection panel is located in the top of the Centix 40 and Centix 50 Premium vacuum unit.
8 Accessories Telescopic tube Radiator/crevice nozzle Adjust the length of the telescopic tube by pressing the button and sliding it in or out. 25. (Maximum length 1000 mm and minimum length 600 mm). For cleaning stairs, we recommend reducing the length of the tube to the minimum. This nozzle is useful for hard-to-reach, restricted areas such as corners, crevices and radiators. Fig. 28 Fig. 25 Fig.
10 Troubleshooting Centix 50 Premium display All work involving the 240 volt mains electricity supply must be carried out by a qualified electrical contractor with full knowledge of the relevant safety regulations. The Centix 50 Premium model has a display that shows relevant status. The display shows the machine’s total operating hours (Run) It also shows the remaining capacity of the filter and dust bag (Filter / Bag).
10.1 Service/maintenance guide - Centix 20 NB! Never vacuum without a filter and dust bag installed. Product How often? Why? How? Dust bag Should be replaced before it becomes completely full, depending on use but normally 2-4 times a year. Poor suction and danger of creating a blockage in the pipe system. Grasp the edge of the lid and open it by pulling upwards.
11 Dimensional drawings Centix 20 / Centix 40 / Centix 50 Premium Dimensional drawings in mm.
CENTIX 60 CENTIX 60 PREMIUM Operating Instructions..................................... 1 Betriebsanleitung........................................... 13 français Notice d’utilisation ......................................... 25 nederlands Gebruiksaanwijzing ....................................... 37 norsk Driftsinstruks.................................................. 49 svensk Bruksanvisning .............................................. 61 dansk Driftsvejledning ........................................
#%.4)8 #%.4)8 02%-)5- #%.4)8 #%.
CENTIX 60 CENTIX 60 PREMIUM english Contents 1 Important safety instructions ............................................................................................2 2 Description 2.1 Operating elements ..............................................................4 3 Before start-up 3.1 3.2 3.3 Assembling the cleaner ........................................................4 Fixing wall bracket ................................................................
CENTIX 60 CENTIX 60 PREMIUM english 1 Important safety instructions Symbols used to mark instructions For your own safety Before using the vacuum cleaner, always read the operating instructions and keep them readily available. This symbol is used to mark safety instructions that must be observed to prevent damage to the vacuum cleaner and its performance. This symbol is used to mark safety instructions that must be observed to prevent damage to persons.
CENTIX 60 CENTIX 60 PREMIUM Use only the type of power cord specified in the operating manual. Do not damage the power cord (e.g. by moving over it or pulling or crushing it). Disconnect the power cord by pulling the plug only (do not pull or tug the power cord). It is recommended that the vacuum cleaner should be connected via a residual current circuit breaker. This stops the supply of electricity if the leakage current to earth exceeds 30 mA for 30 ms or it has an earth tester circuit.
CENTIX 60 CENTIX 60 PREMIUM english 2 Description 2.1 Operating elements See fold-out page at the front of these operating instructions. 1 Handle with cable hook 2 Accessory holder 3 Cleaner switch 4 5 6 7 8 9 Retaining clamp Dirt tank Grip to empty tank Inlet fitting Plug for mobile operation Waste air connection 3 Before start-up 3.1 Assembling the cleaner 3. Take the accessories out of the dirt tank and the packaging. 4.
CENTIX 60 CENTIX 60 PREMIUM 3.3 Fitting suction hose and waste air hose 2 1 1. Suction hose, 1 m: Screw 90° bush (1) on to one end of the suction hose (left thread). 2. Waste air hose, 1 m: Screw rotatable bush ø50 mm (2) on to one end of the suction hose. 3. Connect the hoses to the cleaner and the system as shown in the diagram. english 4 Operation 4.1 Connections 4.1.1 Electrical connection The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply.
CENTIX 60 CENTIX 60 PREMIUM english 4.2 Operation on central extraction system 0 1 2 4.3 Mobile operation 4.3.1 Changing suction hose for mobile operation Connect only plugs to the cleaner socket that have been approved by Alto. 1. Ensure that – the cleaner is switched off – the suction sockets are not activated. 2. Connect the plug of the central extraction system (1) to the control panel. 3. Turn the switch to position „I“. 4. Insert the suction hose in the suction socket.
CENTIX 60 CENTIX 60 PREMIUM 5 Applications and techniques 5.1 Techniques If used correctly, additional accessories, suction nozzles and suction hoses can enhance the cleaning action and reduce the cleaning effort. english Effective cleaning is achieved if you follow just a few guidelines in combination with your own practical experience in special fields. Here are some basic tips. 5.1.
CENTIX 60 CENTIX 60 PREMIUM english 7 Maintenance 7.1 Maintenance plan As required 7.2.1 Emptying dirt tank z 7.2.2 Replacing the filter bag z 7.2.3 Replacing the filter element z 7.2.4 Check that the hose of the level indicator and accessories are not blocked and clean them. z 7.2 Maintenance work 7.2.1 Emptying dirt tank Empty the dirt tank if you use the vacuum cleaner without a filter bag: 1. Remove the upper section of cleaner from the dirt tank. 2.
CENTIX 60 CENTIX 60 PREMIUM 7.2.3 Replacing the filter element 3 2 1 4 1. Remove the upper section of the cleaner from the dirt tank and deposit it with the filter element facing upwards. Do not place the upper section of the cleaner on the guard (1). 2. Turn the filter holder anticlockwise (2) and remove it (3). 3. Carefully remove the filter element. 4. Clean the filter seal (4). Check it for damage and replace it if necessary. 5. Fit a new filter element. 6.
CENTIX 60 CENTIX 60 PREMIUM english Fault ‡ Voltage fluctuations Cause Remedy > Impedance of power supply is • Use a suitable extension too high cord (see sections 1, „Safety instructions“, and 9.4, „Technical data“) • Connect the cleaner to another socket closer to the fuse box. Voltage fluctuations over 7% should not occur if the impedance at the transfer point is ≤0.15 Ω. 9 Further information 9.1 Recycling the vacuum cleaner Make the old cleaner unusable immediately. 1.
CENTIX 60 CENTIX 60 PREMIUM 9.4 english Technical data CENTIX 60 / CENTIX 60 PREMIUM EU Voltage V 230 Mains frequency Hz 50/60 Power consumption W 1200 Fuse A 16 Volume flow (air) max. l/min 3600 Negative pressure max.
CENTIX 60 CENTIX 60 PREMIUM english 9.
#%.4)8 #%.4)8 02%-)5- )NSTALLATION )NSTRUCTIONS )NSTALLATIONSANLEITUNG FRANÎAIS .
CENTIX 60 english Contents 1 Important safety instructions ............................................................................................2 Contents of installation kit ............................................................................................3 2 Planning the installation 2.1 2.2 Selecting a location for the CENTIX vacuum unit.................4 Selecting a location for the vacuum sockets ........................5 3 Installation 3.1 3.1.1 3.1.2 3.2 3.3 3.4 3.4.
CENTIX 60 english Important safety instructions Vacuum unit Always read the operating instructions before starting up the CENTIX vacuum unit, and keep them readily available. Do not cover vacuum unit motor air inlet (on rear of cover), otherwise motor may overheat and shut off.
CENTIX 60 english 1 Contents of installation kit Inst. kit 2 Inst. kit 3 302001193 302001194 Picture Item no. Quantity Quantity 1 PVC tubes, 1.2 m diam. 50.8 Description 10 15 2 90° elbow, long 4 9 3 45° elbow 2 6 4 Tube holder 4 6 5 Tube connecting pieces 8 12 6 90° elbow with 90° branch 1 2 7 12V control cable 25 25 8 Cable tie, 22.
CENTIX 60 english 2 Planning the installation Before installing the system you should answer the following questions: 1. What condition is the property in? • In the planning phase • Carcass complete • Finished 2. How do you wish to install the suction tubes? • On the surface • Concealed • Are empty shafts available? Tips + Tricks: Use the ground plan of your property as a planning basis if possible. 3. What material are the walls made of? 4. Where do you wish to locate the vacuum unit? 5.
CENTIX 60 2.2 Selecting a location for the vacuum sockets The vacuum sockets should be located as follows: – In easily accessible locations – Near light switches or door frames – Never behind a door – At a height of approx. 30-40 cm – At a height of approx.
CENTIX 60 english 3 Installation The text figures in brackets relate to the table in section 1 “Contents of installation kit”. 3.1 Suction tube installation 3.1.1 General rules when installing suction tubes Rule 1 The tubes (1) can be installed vertically or horizontally. If the tubes are installed horizontally, ensure that they slope downwards toward the vacuum unit. Rule 2 Always install a short 90° elbow (12) after the socket (10) and the installation frame (11).
CENTIX 60 Rule 7 Always apply adhesive to the tube, never put into the socket end. english Rule 8 The tubes must always slope downwards from the vacuum sockets to the vacuum unit. Rule 9 It is advisable to install the vacuum socket that is furthest away from the vacuum unit first.
CENTIX 60 english 1) New buildings Tips + Tricks: • Do not glue the vertical suction tube to the horizontal suction tubes in the ceiling immediately. • When the piece of tube is being sealed into the ceiling it must be protected with a casing so that the tube can be replaced with a longer one after the ceiling has been cast if necessary. • Create slits for the suction tubes in the finished wall. This makes the masonry work easier.
CENTIX 60 2b) Existing houses, surface installation english The suction tubes can also be surface mounted. Experience has shown the following to be advisable: I. Properties with cellar, single storey II. Properties with cellar, multiple storeys III. Properties without cellar I. Route tubes along cellar ceiling. Makes holes in the ceiling at the locations in which the vacuum sockets will subsequently be fitted. The vacuum sockets can be conveniently installed as floor vacuum sockets in the first storey.
CENTIX 60 english 2c) Use of empty shafts or unused chimneys In a property with an unused chimney or empty shafts, the tubes can be vertically routed from the vacuum sockets to the vacuum unit inside the chimney through the floors. 1. Determine the positions of the vacuum sockets. Ensure that the vacuum sockets are not directly opposite each other but have a height difference of at least 17 cm. 2. Then draw a diagram showing the socket arrangement with exact distances and lengths. 3.
CENTIX 60 3.2 Installing the control cable You can route and connect the control cables yourself, since the control signals are transferred with a low voltage of 12V. english 1. The two-wire control cable (7) must be routed from each vacuum socket along the tubes to the vacuum unit. The control cable is attached to the tubes using the supplied cable ties (8). 2. The cable is connected to the branching point using a connector block (14).
CENTIX 60 english 3.3 Installing the vacuum sockets The vacuum sockets consist of the following components: 1. Vacuum socket (10) 2. Installation frame (11) 3. Short 90° elbow (12) Vacuum socket installed beneath plaster The installation frame (11) is installed flush with the plaster. 1. Before plastering: fit access cover (9) to installation frame so that installation frame is not damaged or soiled. 2. Remove access cover when wall covering is complete. 3.
CENTIX 60 Tips + Tricks: • IMPORTANT: The socket will subsequently be in the same location as the installation frame. Please ensure that the frame is aligned in a perpendicular position. • To prevent the tube system from being blocked by long objects: – Use short 90º elbow (12) immediately after vacuum socket. Connect short limb to installation frame and long limb to vacuum socket. – If you cannot use a short 90º elbow (12), e.g. with surface installations, avoid sucking up long objects.
CENTIX 60 english 3.4.1 Assembling and positioning the vacuum cleaner wall mounting 1. Position the vacuum at a maximum height of approx. 90 cm (see Tips + Tricks). Adapt the location to your requirements. 2. Notes on installing wall mount: see CENTIX 60 operating instructions. Tips + Tricks: • Ensure that the top of the vacuum cleaner is easy to remove and that the filter bag can be disposed of without problems. 3.4.2 Installing the suction hose 1.
#%.4)8 /PERATION START UP 3TATIONARY OPERATION )NSERT END OF CONNECTING TUBE THAT IS ATTACHED TO THE VACUUM SOCKETS INTO ONE OF THE TWO SOCKETS OF THE #%.4)8 VACUUM UNIT ENGLISH -OVE SWITCH ON #%.4)8 VACUUM UNIT TO POSITION ) 6ACUUM UNIT MUST NOT START )NSERT SUCTION HOSE DIAM X M INTO ONE OF THE INSTALLED VACU UM SOCKETS 4HE VACUUM UNITS STARTS UP 2EMOVING THE SUCTION HOSE FROM THE SOCKET STOPS THE VACUUM UNIT -OBILE OPERATION 3EE #%.
CENTIX 60 english 5 Troubleshooting Faults that affect the vacuum unit and its accessories are described in the CENTIX vacuum unit operating instructions. Fault ‡ Motor will not start Cause > Control cable disconnected Remedy • • ‡ Motor starts, but system > Vacuum sockets not sealed does not operate at original power > Tube system damaged • • > Glued connections to suction • tubes not tight > Test vacuum unit in mobile • operation. If full suction power is available the tube system is blocked.
CENTIX 60 english 6 Accessories 6.1 List of optional accessories Picture Item number 302001288 9 m suction hose, auto S/S 302001263 Vac Pan, white 302001257 Vacuum socket, SET, white 54118 Turbo Nozzle 63990 Filter element 30200449 6.2 Spare parts Description Filter bag, pack of 5 Contact your friendly ALTO dealer or see spare part list at www.alto-online.
INTERNET http://www.alto-online.com DENMARK ALTO Danmark A/S Industrikvarteret 9560 Hadsund Tel.: +45 7218 21 00 Fax: +45 7218 21 05 E-mail: salg@alto-dk.com SLOVENIA Wap ALTO čistilni sistemi, d.o.o. Letališka 33 SLO-1110 Ljubljana Tel.: +368 15 20 62 00 Fax: +368 15 20 62 10 E-mail: wap@siol.net SUBSIDIARIES FRANCE ALTO France S.A. B.P. 44, 4 Place d’Ostwald 67036 Strasbourg Cedex 2 Tel.: +33 3 88 28 84 00 Fax: +33 3 88 30 05 00 E-mail: info@alto-fr.com SLOWAKIA Wap ALTO čistiace systémy s.r.o.