Operation Manual
13
MULTICLEANER 7-53
Original Instructions
6.5 Ambient temperature,
operation/storage
During operation the ambient temperature must always be above
+10 degrees Celsius. During storage the temperature must never
go below freezing point unless the MULTICLEANER has been frost
protected as described in section 7.5.1.
6.6 Inventory in aisle The sides of the inventory in the aisle, towards which the MUL-
TICLEANER regulates its course by means of the two ultrasonic
sensors must be present and even. The ultrasonic sensors can be
regulated up and down and must be set to touch on an even side.
All gaps exceeding 50 mm in the inventory side should be covered.
If the MULTICLEANER cannot detect the inventory side, it will
proceed forwards for approximately 10 seconds. Then the MULTI-
CLEANER will report an error because of a missing inventory side.
The end wall of the aisle against which the rubber bumpers of the
MULTICLEANER are activated, must be plane and without any
sharp objects which may puncture the bumpers. The height of the
plane surface must be 450 mm at a minimum. Profiled end walls
such as steel gates must be covered with a plate.
If the tower and the arm are placed in a position so that during the
aisle washing they protrude backwards above the bumper, an object
must be placed so that the rear bumper can be activated during
backward movement.
6.7 Floor finish in aisle In connection with washing of the aisle it is important that the dirt
which the MULTICLEANER drags along can be led away in a natu-
ral way as the machine is progressing. A slotted floor is preferred off
course, but if it is a solid floor, there must be a clearance under the
gates of 40 mm at a minimum. If it is a combination of a slotted and
a solid floor, a clearance below the gates is not necessary.
Note! Large amounts of muck and foreign bodies as for instance
remains of concrete and stones must be removed before starting
the cleaning.
6.8 Pens The optimal layout of a pen will be :
The depth of the pen does not increase 4.8 m.
The plastic inventory and the latch do not exceed 1000 mm in the
height.
The stomas are perpendicular to the aisle.
The width of the aisle is 800 mm.
Stomas in the aisle.
Automatic feeders, down-leads and water pipes are placed at least
2 m inside the pen from the front edge of the inventory side in the
aisle, enabling the washing arm to reach the middle of the pen.
On potential rest areas to the stoma area there is a minimum gradi-
ent of 3%.
3/4" water connection at one of the ends of the aisle. Availability of
17 l water per minute.
CEE-plug at the end of the aisle, 400 V / 16 A.