8 Operation
9 Maintenance
8.1 Indicator lamp The MULTICLEANER features an indicator lamp on the horizontal
arm indicating the working condition of the robot.
Gone off: : The MULTICLEANER must
be programmed.
Flashing light: : Auto-routine in progress.
Constant light: : The MULTICLEANER has
finished the auto-routine or it
is in error-proof condition -
see list of alarms.
9.1 General Always visually check the robot before starting it up. If you find loose
shields or any other loose parts, these must be mounted/fixed again
to avoid stoppage and worsening of the fault. If the cables or the like
are damaged, do not start up the MULTICLEANER until the damage
has been fixed.
9.2 Maintenance
procedures
9.2.1 Service interval on
motor/pump unit.
Check the following:
Weekly
Each 100
hours of ope-
ration
Each 6
months or
each 500
hours of
operation
As required
Check oil level
Renew oil
Clean high pressure nozzle
Clean water filter
Replace o-rings in banjo bolt in
nozzle head
Inspection of pressure in tyres
The life of the various components in the pump very much depends on the number of particles in the water