Operation Manual

21
1)
Options / model variants
Original instructions
NEPTUNE 5-50 FA SPECIAL
9.4 Technical Data
NEPTUNE 5-50 FA SPECIAL
Voltage200V/3~/50Hz
EU
Voltage200V/3~/60Hz
Voltage230V/1~/60Hz
Voltage400V/3~/50Hz
Voltage400/230V/3~/50Hz
Voltage220/440V/3~/60Hz
Fuse
A 13
Powerrating
kW 6/6.1
Powerconsumption
A 10.5
Typeofprotection
IPX5
Workingpressure
bar(MPa) 170(17)
PermissiblepressureP
max
bar(MPa) 250(25)
Volumeow(max)
l/h 960
VolumeowQ
IEC
l/h 900
Highpressurenozzle
0530
Temperaturet
max
,hotwater °C 90
Temperaturet
max
,steam °C 150
Max.waterinlettemperature
°C 40
Max.waterinletpressure
bar(MPa) 10(1)
Dimensionslxwxh
mm 1240x800x1185
Weight
kg 179
Calculatedsoundpressureatadistanceof
1mEN60704-1L
pA
+/-K
pA
*
dB(A)
77
+/-1,5
SoundpowerlevelL
wAMAX
includingK
wA
=1,5dB*
dB(A) 93
VibrationISO5349
m/s² <2
Recoilforces
N 37/38
Heatingcapacity
kW 78
Fueltank
l 35
DetergenttankA/B
l 15/10
Oilquantity
l 0.75
Oiltype
BPEnergolGR-XP220
*Noiseemissionacc.toEN60335-2-79ZAA.2.7