Voltage 230 V / 1~/ 50Hz DK EU
Fuse A 13 13
Power rating kW 3.0 3.0
Protection degree IPXX IPX5 IPX5
Working pressure bar (MPa) 140 (14) 140 (14)
Volume flow (max.) l/h 610 610
Volume flow Q
IEC
l/h 540 540
Max. water inlet temperature °C 50
Max. water inlet pressure bar (MPa) 10 (1)
Dimensions l x w x h mm 555 x 290 x 275
Weight kg 26 26
Noise pressure level at a distance of 1 m EN
60704-1
dB(A)
86.8 86.8
Noise power level dB(A) 99.3 99.3
Torque N 20 20
Oil quantity in pump ml 150
Oil type HV68
Hand/arm vibration level m/s
2
< 2.5
EU Declaration of Conformity
Product:
High Pressure Washer
Type:
POSEIDON 2-26 PORTABLE
The design of the unit corre sponds to
the following pertinent regulations:
EC Machine Directive 2006/42/EC
EC Low-voltage Directive 2006/95/EC
EC EMC Directive 2004/108/EC
EC RoHS Directive 2011/65/EC
EC Noise Emission Directive 2000/14/EC
Applied harmonised standards:
EN 292-1, EN 292-2, EN 60335-2-79
EN 55014-1 (2002), EN 55014-2 (2001), EN 61000-3-2 (2006)
Applied international standards and
technical specifi cations:
IEC 60335-2-79
Name and address of the person
autho rised to compile the technical
fi le:
Anton Sørensen
General Manager, Technical Operations EAPC
Nilfi sk-Advance A/S
Sognevej 25
DK-2605 Brøndby
Identity and signature of the person
empowered to draw up the declaration
on behalf of the manufacturer:
Anton Sørensen
General Manager, Technical Operations EAPC
Nilfi sk-Advance A/S
Sognevej 25
DK-2605 Brøndby
Place and date of the declaration:
Hadsund, 04.11.2013
52
Original instructions
POSEIDON 2 PORTABLE
8.2 Guarantee
Our general conditions of busi-
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.
8.3 Technical Specifications
8.4 EU Declaration of Conformity