4.1.2 High pressure hose -
to outlet point
(continued)
Pipeline, max. length:
UNO BOOSTER DUO BOOSTER
Ø15 x 1.5 - max. 50 m Ø15 x 1.5 - max. 25 m
Ø15 x 1.5 - max. 180 m Ø18 x 1.5 - max. 120 m
Ø15 x 1.5 - max. 500 m Ø22 x 2.0 - max. 250 m
When using max. pipe lengths, only use a high pressure hose of 10
m.
4.1.3 Spray handle -
accessories
4.1.4 Selection of
spray lance
(only UNO BOOSTER)
You may use a double spray
lance as well as a single spray
lance with the ma chine. The
ma chine has been optimized
to use spray lances with a type
0640 nozzle. The max. pres sure
of the machine can be reduced
by using noz zles with a wider
di am e ter. See diagram.
P: Nozzle pressure
Q: Water volume
C: Colour code
MULTIPRESSURE
P bar Q l/min. C
27 17 White
50 17 Brown
80 17 Blue
107 17 Orange
152 17 Shiny
2
1
1. Pull forward the quick
coupling trigger (1) of the
spray handle.
2. Insert the nipple of the
spray lance (2) in the quick
coupling and release the
trigger.
3. Pull forward the spray lance
or any other accessory to
ensure correct mounting
before starting the machine.
NOTE!
Clean nipple of any impurities
each time the spray lance has
been dismounted.