4.1.6 Application of
detergents (external)
If you want to apply detergents
or disinfectants these should be
dosed to the water through an
injector. In conjunction with the
injector it may be ad van ta geous
to use a wall rack on which
spray lances, 2 pcs. of 25 l
Outlet point with detachable
injector
To be attached to the quick
coupling of the high pressure
cock.
To be used for dosing of
low-foaming detergents or
disinfectants.
Dosage 1-8%.
Outlet point with detachable
foam injector
To be attached to the quick
coupling of the high pressure
cock.
To be used in conjunction with
foam lance for application of
high-foaming de ter gents or
disinfectants.
Dosage 1-5%.
Outlet point with cleaning
trolley and foam injector
To be attached to the quick
coupling of the high pressure
cock.
To be used in the same way as
“Outlet point with detachable
foam injector”.
Makes it possible to place 4
spray lances, 2 pcs. of 25 l
containers as well as 20 m high
pressure hose.
containers as well as 10 m high
pressure hose can be placed.
Below you will fi nd various
types of outlet points with
injectors.
4.1.5 Function (only DUO
BOOSTER)
The machine is equipped with
2 high pressure pumps. These
are controlled so that they will
start and stop according to
requirement. If the machine
is connected to a pipeline
with 2 users, the machine
will automatically adjust the
numbers of pumps to run. If the
pressure drops below 155 bars,
an extra pump will start. If the
pressure rises to above 182
bars, a pump will stop.
It is important to use the correct
lances/nozzles for the machine.
The nozzle size can be read
from the data plate on the