8 Technical Data
9 Warranty
• that only original
accessories have been
applied.
• that the product has not
been exposed to abuse such
as knocks, bumps or frost.
• that the instructions in the
manual have been carefully
observed.
A warranty repair comprises the
replacement of defective parts,
but it does not cover freight and
packaging charges. Besides we
refer to national Sale of Goods
Act.
Any illegitimate guarantee
repair will be invoiced. (I.e.
malfunctions due to causes
mentioned in section “7.0
Trouble shooting” of the
instruction manual).
Your Nilfi sk-ALTO product is
guaranteed for 12 months from
date of purchase (purchase
receipt must be presented) on
the following conditions:
• that defects are attributable
to fl aws or defects in
materials or workmanship.
(Usual wear and tear as well
as misuse are not covered
by the guarantee).
• that repairs have not been
carried out or attempted
by other than Nilfi sk-ALTO-
trained service staff.
Model
UNO BOOSTER
EXTENDED
DUO BOOSTER 7
Pump pressure
1)
bar 160 180
Water volume, min./max. pressure l/h 1200/1120 2506/2360
Water tank, volume litres 3 7.5
Water connection:
Max. pressure, inlet water
Min. pressure, inlet water
Max. temperature, inlet water
bar
bar
°C
10
1.0
70 (80, see section 3.4)
10
1.5
70 (80, see section 3.4)
Spray lance:
Nozzle type
Thrust, max. N/kp
0640
47/4.8
0640
47/4.8
Pipeline, max. length
m
Ø12 x 1.5 - max. 50
Ø15 x 1.5 - max. 180
Ø18 x 1.5 - max. 500
Ø15 x 1.5 - max. 25
Ø18 x 1.5 - max. 120
Ø22 x 2.0 - max. 250
When using max. pipe lengths, only use a high pressure hose of 10 m.
Oil:
Oil type
Oil quantity l
Castrol Alphasyn 150
1.0
Castrol Alphasyn 150
2.0
1)
When using a 10 m (3/8") high pressure hose.
Sound pressure level LpA measured in accordance with ISO 11202 [DISTANCE 1m] [FULL LOAD]:
79 dB(A).
Data stated at 12°C hot inlet water.