machine should include a residual current device that
will interrupt the supply if the leakage current to earth
exceeds 30 mA for 30 ms.
Inadequate extension cables can be dangerous. If an
extension cable is used, it shall be suitable for outdoor
use, and the connection has to be kept dry and off the
ground.
• Nilfi sk recommends use of an extension cable drum
when cable extension is needed which keeps the
socket at least 60 mm above the ground.
If the electric cable is damaged, it must be replaced
by an authorized Nilfi sk distributor or similar qualifi ed
person in order to avoid a hazard.
Water connection
This high pressure washer is only allowed to be con-
nected with the drinking water mains, when an appro-
priate backfl ow preventer has been installed, Type BA
according to EN 60335-2-79.
The backfl ow preventer can be ordered under number
106411177.
As soon as drinking water has fl own through the back-
ow preventer, it is no longer regarded as drinking
water.
Operation by suction (e.g. a rainwater vessel) is car-
ried out without a backfl ow preventer – see Connec-
ting to a pressureless water supply”. The machine
can be connected to water mains with a max. inlet-
pressure of 1 MPa/10 bars and max. 60°C.
Safety devices
Locking device on spray handle:
The spray handle features a locking device. When the
pawl is activated, the spray handle cannot be ope-
rated.
Thermal sensor:
A thermal sensor protects the motor against overload-
ing. The machine will restart after a few minutes when
the thermal sensor has cooled.