User’s ZX-R8204 Reader User’s Manual Ningbo K&D IOT Technology Co.
User’s Welcome you to be the user of Nation RFID products! 2 Manual
User’s Manual Content 1 2 3 4 Product Overview.......................................................................................................................... 5 1.1 Product characteristics......................................................................................................5 1.2 Main uses and scope of application............................................................................. 5 1.3 environment condition........................................................
User’s Manual Safety Instructions Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Invengo equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the cautions. Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
User’s Manual 1 Product Overview 1.1 Product characteristics ZX-R8204 RF module is a high-performance RFID module designed and developed by Nation RFID. It is equipped with four SMA antenna interfaces. It has the leading reception sensitivity in the industry. The single tag recognition rate is fast, and the multi-tag processing ability is strong.
User’s 1.4 Manual Shape size The volume parameters of ZX-R8204 RF module are as follows: : 71.5mm x 52.5mm x 7.
User’s Manual 2 Demo Operational instructions 2.1 About Demo Software The Demo software is used to set system parameters and perform read operation on Nation RFID ZXR8204 series reader and ISO compliant transponders 2.2 Demo System Requirements ● Supported Operating Systems Windows Server 2003; Windows XP Service Pack 2; Windows Vista; Windows 7 ; Windows 10 These systems are 64-bit operating system. The USB driver does not support 64- bit OS for the time being..
User’s 2.4 2.4.1 Manual Demonstration software operation Connect Reader All functions can be operated only after successful connection. 2.4.1.1 Serial Communication Connection Double-click on the icon to start Demo software. Each icon in the main interface toolbar is gray to indicate that the reader is not connected yet.
User’s Manual Figure 2: RS232 Successful connection 2.4.2 Data display area Click on the button,The data display area will be displayed, as shown in Figure 3.
User’s Manual Type:Label type:6C、6B、GB Three kinds; EPC:EPC Data of Labels; TID:TID Data of Labels; UserData:User data area; ReserveData:Reserved area data, label password data, etc; TotalCount:Total number of tag reads; ANT1:Number of Reads of Antenna No.1; ANT2:Number of Reads of Antenna No.2; ANT3:Number of Reads of Antenna No.3; ANT4:Number of Reads of Antenna No.4; ANT5:Number of Reads of Antenna No.5; ANT6:Number of Reads of Antenna No.6; ANT7:Number of Reads of Antenna No.
User’s Manual 2.4.3 Equipment configuration The Demo main interface chooses“Device Control”->“Device Configuration” and pops up the“Device Configuration”dialog box, as shown in Figure 6. Figure 6: Equipment configuration The upper left of the window is the serial port parameters. As shown in Figure 7, click “ Get ” to get the serial port communication baud rate parameters of the reader, and click“Set”to set the serial port communication baud rate of the reader.
User’s Manual Figure 7: Serial port parameters 2.4.4 EPC baseband parameters The upper left of the window is the EPC baseband parameters. As shown in Figure 8, click“Get”to get the EPC baseband parameters of the reader . Click“Set”to set reader EPC baseband parameters.
User’s Manual Changing the configuration of baseband parameters can change the actual effect of reading (it can be reasonably configured according to the application scenario, but it needs to be operated under the guidance of our engineers). EPC baseband rate provides six choices: Tair = 25us, FM0, LHF = 40KHz; intensive reading mode; Tair = 25us, Miller 4, LHF = 300KHz; Fast read mode; Tari = 25us, Miller 4, LHF = 320KHz; 255/AUTO. Session offers four options: 0;1;2;3.
User’s Manual 2.4.6 Frequency Hopping Management Select frequency hopping in the left menu bar of the RFID configuration, as shown in Figure 10.
User’s determine。if you want to select the full frequency hopping, click“ Manual ” , then click on the right side. The list box shows all the frequencies in this band. Click“Set”to see Figure 12. If you click“ ”on the right list box, all frequencies will be cleared.
User’s Figure 12: Manual Frequency point selection 2.4.7 Equipment Information The main interface chooses “Tool” - >“ ”Device Information, as shown in Figure 13. After clicking on the icon, a “Device Info”pop-up window appears, as shown in Figure 14.
User’s Figure 14: Equipment Information Bullet Window 19 Manual
User’s Manual 3 Packaging and Storage 3.1 Packaging In order to facilitate storage and transportation in the future, the ZX-R8204 RF module is opened and the packaging box and materials are properly preserved. In addition to the module, the package also includes the accessories needed for the use of the product. Please confirm whether the products and accessories are complete according to the product packing list.
User’s 4 Manual Services and Support Ningbo K&D IOT Technology Co., Ltd,Ltd Advising customers Our aim is to provide customers with high quality products, follow-up will continue to optimize and update our products to ensure that our product performance is in the forefront of similar products. This user manual will be different from the actual equipment in terms of product characteristics, composition and design. We will provide corrections in time.
User’s Manual Warranty Notes: In order to provide better service, our company randomly attaches a warranty card, please keep it well, in order to enjoy the proper service. 1、Since the date of purchase, the product has not been dismantled and repaired in normal operation, and enjoys warranty service within one year.
FCC warning: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Warning: The module is limited to OEM installation ONLY The antenna installation must be professional installation, and does not permit use of any antenna with the transmitter; the permitted types of antenna must be specified. The module cannot be sold via retail to the general public or by mail order; it must be sold to authorized dealers or installers only. The end product intended use is not for consumers and general public; rather device is generally for industrial/commercial use.
WARNING: The Federal Communications Commission warns that changes or modifications of the radio module within this device not expressly approved by Ningbo K&D IOT Technology Co., Ltd could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including any interference that may cause undesired operation.