Owner's Manual

LUBRICANT
MTC-17
C
D
E
F
G
H
I
K
L
M
A
B
MTC
Lubricant Adjusting Procedure for Components Replacement Except Compressor
After replacing any of the following major components, add the correct amount of lubricant to the system.
Amount of lubricant to be added
*1: If refrigerant leak is small, no addition of lubricant is needed.
Lubricant Adjustment Procedure for Compressor Replacement
1. Before connecting the recovery/recycling recharging equipment to the vehicle, check the recovery/recy-
cling recharging equipment gauges. No refrigerant pressure should be displayed. If OK, recover refriger-
ant from equipment lines.
2. Confirm refrigerant purity in supply tank using recovery/recycling recharging equipment and refrigerant
identifier. If NG, refer to MTC-3, "
Contaminated Refrigerant" .
3. Connect recovery/recycling recharging equipment to the vehicle. Confirm refrigerant purity in vehicle A/C
system using recovery/recycling recharging equipment and refrigerant identifier. If NG, refer to MTC-3,
"Contaminated Refrigerant" .
4. Discharge refrigerant into the refrigerant recovery/recycling recharging equipment. Measure lubricant dis-
charged into the recovery/recycling recharging equipment.
5. Drain the lubricant from the old (removed) compressor into a graduated container and recover the
amount of lubricant drained.
6. Drain the lubricant from the new compressor into a separate, clean container.
7. Measure an amount of new lubricant installed equal to amount drained from old compressor. Add this
lubricant to new compressor through the suction port opening.
8. Measure an amount of new lubricant equal to the amount recovered during discharging. Add this lubricant
to new compressor through the suction port opening.
9. If the liquid tank also needs to be replaced, add an additional 5 ml (0.2 US fl oz, 0.2 Imp fl oz) of lubricant
at this time.
Do not add this 5 ml (0.2 US fl oz, 0.2 Imp fl oz) of lubricant if only replacing the compressor.
Part replaced
Lubricant to be added to
system
Remarks
Amount of lubricant
ml (US fl oz, Imp fl oz)
Evaporator 75 (2.5, 2.6)
Condenser 75 (2.5, 2.6)
Liquid tank 5 (0.2, 0.2)
Add if compressor is not
replaced.
In case of refrigerant leak
30 (1.0, 1.1) Large leak
Small leak *1