Owner's Manual

LUBRICANT
MTC-19
C
D
E
F
G
H
I
K
L
M
A
B
MTC
Revision: March 2005 2005 Altima
LUBRICANT PFP:KLG00
Maintenance of Lubricant Quantity in Compressor EJS002S4
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage has occurred. It is important to maintain
the specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
CHECKING AND ADJUSTING
CAUTION:
If excessive lubricant leakage is noted, do not perform the lubricant return operation.
Start the engine and set the following conditions:
Test Condition
Engine speed: Idling to 1,200 rpm
A/C switch: On
Blower speed: Max. position
Temp. control: Optional [Set so that intake air temperature is 25° to 30° C (77° to 86°F).]
Intake position: Recirculation ( )
Perform lubricant return operation for about ten minutes
Adjust the lubricant quantity according to the following table.
Lubricant Adjusting Procedure for Components Replacement Except Compressor
After replacing any of the following major components, add the correct amount of lubricant to the system.
Amount of Lubricant to be Added
*1: If refrigerant leak is small, no addition of lubricant is needed.
Lubricant Adjustment Procedure for Compressor Replacement
1. Before connecting recovery/recycling equipment to vehicle, check recovery/recycling equipment gauges.
No refrigerant pressure should be displayed. If NG, recover refrigerant from equipment lines.
2. Connect recovery/recycling equipment to vehicle. Confirm refrigerant purity in supply tank using recovery/
recycling equipment and refrigerant identifier. If NG, refer to MTC-4, "
Contaminated Refrigerant" .
3. Confirm refrigerant purity in vehicle A/C system using recovery/recycling equipment and refrigerant identi-
fier. If NG, refer to MTC-4, "
Contaminated Refrigerant" .
4. Discharge refrigerant into the refrigerant recovery/recycling equipment. Measure lubricant discharged into
the recovery/recycling equipment.
5. Drain the lubricant from the “old” (removed) compressor into a graduated container and recover the
amount of lubricant drained.
6. Drain the lubricant from the “new” compressor into a separate, clean container.
Lubricant type : NISSAN A/C System Lubricant Type DH-PS or equivalent
Part number : KLH00-PAGS0
Part replaced
Lubricant to be added to system
Remarks
Amount of lubricant
m (US fl oz, Imp fl oz)
Evaporator 75 (2.5, 2.6)
Condenser 75 (2.5, 2.6)
Liquid tank 5 (0.2, 0.2) Add if compressor is not replaced.
In case of refrigerant leak
30 (1.0, 1.1) Large leak
Small leak *1