User guide
- 23 -
First Aid
Emergency responders may not be familiar with a Ni-MH electrolyte exposure when rendering aid to a patient.
Exposure to the electrolyte is unlikely except in a catastrophic crash or through improper handling. Utilize the
following guidelines in the event of exposure.
• Absorption
¾ Perform gross decontamination by removing affected clothing and properly disposing of the
garments.
¾ Rinse the affected area with water for 20 minutes.
¾ Transport patients to the nearest emergency medical care facility.
• Inhalation in non-fire situations
¾ Toxic gases are given off as by-products of combustion. All responders in the Hot Zone should
wear the proper PPE for fire fighting, including SCBA.
¾ Move patients from the hazardous environment to a safe area and administer oxygen.
¾ Transport patients to the nearest emergency medical care facility.
• Ingestion
¾ Do not induce vomiting.
¾ Allow patient to drink large quantities of water to dilute the electrolyte (never give water to an
unconscious person).
¾ If vomiting occurs spontaneously, keep the patient’s head lowered and forward to reduce the
risk of asphyxiation.
¾ Transport patients to the nearest emergency medical care facility.
¾ Contact Poison Control Center at 1-800-222-1222
Submersion
When fully or partially submersed, an Altima Hybrid can be safely handled by following these
recommendations:
• Remove the vehicle from the water.
• Drain the water from the vehicle, if possible.
• Follow the immobilizing and disabling procedures.
DANGER:
• The Ni-MH battery electrolyte is a caustic alkaline (pH 13.5) that is damaging to human tissues. To
avoid injury by coming in contact with the electrolyte, wear proper personal protective equipment.