Installation and Operation Manual DL2105 RS232 Extender NITEK TM Northern Information Technology, Inc. 766 West Algonquin Road • Arlington Heights, IL 60005 PHONE (847) 718-0600 • FAX (847) 718-0850 Internet: www.nitek.net • E-mail:INFO@nitek.net CAT.NO.1349.
System Specifications DL2105 system includes the following: (1) DL2105 transmitter, (1) DL2105 receiver and (2) wall power transformer DL2105 transmitter unit Size 1.1"H x 2.6"W x 4.3"D Power Requirements 14 to 18 VDC @ 100mA Input RS232 Output Extended RS422 for use up to 12,000 feet DL2105 receiver unit Size 1.1"H x 2.6"W x 4.
Installation The DL2105 transmitter unit is connected at the sending end. It should be located no more then 20 feet form the RS232 source. The twisted pair to the receiver unit can be up to 12,000 feet. At the receiving end the receiver must also be located within 20 feet of the unit needing the RS232 connection. There are several diagrams on the following pages showing the most common ways to connect the DL2105. Connect the DL2105 as outlined in these diagrams.
PC Any system using RS232 for communication RS232 Signal TX and GND RS232 Signal RX and GND NITEK TM DL2105 Transmitter TM wall transformer (included) NITEK DL2105 Receiver wall transformer (included) Twisted Pair up to 12,000 ft Twisted Pair up to 12,000 ft NITEK TM DL2105 Receiver TM wall transformer (included) NITEK DL2105 Transmitter wall transformer (included) RX and GND RS232 Signal TX and GND RS232 Signal Remote System Any system using RS232 for communication Standard Full
Any system using RS232 for communication PC RS232 Signal TX and GND NITEK TM DL2105 Transmitter wall transformer (included) Twisted Pair up to 12,000 ft This multi-drop configuration allows for easy distribution of an RS232 communicaion signal.
Troubleshooting Problem Fix/Cause Data does not appear to be going to the far end ✔ Behind the bottom cover are a POWER and a DATA LED. These LEDs are in both the transmitter and the receiver units. Make sure that the power is ON and that the DATA LED comes ON when you are sending DATA. ✔ Check the twisted pair for shorts to ground and between wires as well for open wires. ✔ If you are not sure of the twisted pair polarity; + and -. Try reversing the twisted pair at one end.
POWER 14 - 18 VDC 100mA MADE IN USA EARTH GROUND WIRE + CONNECT TO RS232 TX RS232 GROUND TWISTED PAIR + OUT TWISTED PAIR - OUT POWER 14 - 18 VDC 60mA MADE IN USA EARTH GROUND WIRE + TWISTED PAIR + IN TWISTED PAIR - IN RS232 GROUND CONNECT TO RS232 RX NITEK TM FROM pair twisted TM EARTH GROUND DL2105 receiver NITEK EARTH GROUND DL2105 transmitter 54-045-0102 RS232 RX RS232 GND TO from RS232 TX RS232 GND RS232 Extender EARTH GROUND DL2105 transmitter pair twisted EARTH GROUND D