User's Guide

eNBioAccess-T2 User Guide 11
12F, Daemyung Valeon bldg., 127, Beobwon-ro,
Songpa-gu, Seoul, Korea (05836)
Tel : 02-6488-3232 , Fax : 02-6488-3099,
E-Mail :customer@nitgen.com http://www.nitgen.com
1.2.3.4. Terminal <- > LC015B wiring
Category
T2 terminal (Line name)
LC015B
RS485A
R4A (green)
485A
RS485B
R4B (blue)
485B
ground connection
GND (black)
GND
DOOR MONITOR
IN1(If this pin is not used,
connect to GND Pin.)
INSIDE OPEN
IN0
DC12V (LC015B separate power
supply)
DC12V IN
ground connection (Power only
for LC015B)
GND
But, door open time can be set with DIP SWITCH of LC015B (Maximum open time is 5 sec.)
1.2.3.5. Terminal <- > EM Type Door Lock wiring
Category
T2 terminal (Line name)
EM Door Lock
Lock
L1NC (Green)
+
GND
GND (Black)
-
Door Monitor
DM0 (Black)
NC(Normal Close)
1.2.3.6. Terminal <- > WIEGAND Device wiring
Category
T2 terminal (Line name)
WIEGAND Device
WIEGAND INPUT0
WI0(갈색)
Wiegand output0
WIEGAND INPUT1
WI1(보라)
Wiegand output1
WIEGAND OUTPUT0
WO0(주황)
Wiegand input0
WIEGAND OUTPUT1
WO1(노랑)
Wiegand input1
GND
GND (검정)
GND