3.10.2.2. LOCK1 OPEN TIME
It sets the time to give the signal when LOCK 1 sets 2. STRIKE/OK. Strike type means the
time from opening to locking the door after authenticating. The default value is 3 seconds and
the input range is 1 to 20 seconds.
3.10.2.3. LOCK2 type
NONE
When not using
FAIL IND
When connecting the light to mark authentication failure in Lock 2
MOTOR2
When connecting motor lock
3.10.2.4. LOCK2 OPEN TIME
If Lock 2 sets FAIL IND, it sets the time to give the signal. The default value is 3 seconds and the
input range is 1 to 20 seconds.
3.10.2.5. OPEN ALARM
When the door open time expires and the door open alarm time is exceeded, the alarm sounds.
The default value is 5seconds and the input range is 0 ~ 20 seconds. If it is set to 0, it will not beep. If it
is set to 1 ~ 20 seconds, it will beep.
Door open time
Open alarm time
DOOR OPEN state
alarm