The NivisLink application also gives the user the flexibility to directly control the functional registers of the RF transceiver.
This gives the user complete control over every aspect of the RF functionality of the RF Sniffer. These register should only
be overwritten by users that are knowledgeable of the RF transceiver. For a list and explanation of each RF register
consult the datasheet of the RF transceiver.
3.6 Additional Features
The NivisLink application also permits the user to view various other parameters of the RF Sniffer.
GET RSSI tab – displays the value present in the Received Strength Indicator register of the RF transceiver
GET AFC - displays the value present in Automatic Frequency Correction register of the RF transceiver
GET TEMPERATURE tab – displays the temperature value indicated by the internal temperature sensor of the
MSP430 processor
GET VOLTAGE – displays the supply voltage of the processor as read by an internal analog line of the MSP430
processor
4. RF Exposure Limit Warning
To comply with FCC’s RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this
transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter.
5. Compliance Statement (Part 15.19)