User's Manual

ILD-IN’O User Guide
All Rights Reserved nke Watteco® ILD-IN’O User Guide
Page 5 of 9
1 INTRODUCTION
This document describes the usage of the ILD and IN’O sensor. It is necessary to read the IPSensor User Guide
in prerequisite for all generic information.
2 START-UP
The ILD and IN’O sensors manage two different power supplies, one is external and energizable in 9-15V the
other one is internal on the battery. To use the external alimentation, just connect the right alimentation on
the “Ext power” connector.
Connect wires on Inputs and Outputs which will be used. For connector, it is preferable to use several single
wires with a gauge of 20-26 AWG. As the connectors pluck the wires plugged to their bottom at about 4mm of
the wire-end, strip the wires on about 5 to 6 mm of their extremity pluged into the connector.
For water protection, it is recommended to use moulted cable.
The housing is intended to be installed inside or outside a building but to the shelter of a vertical splash water
and direct sunlight.
Switch on the switch “Power Off” to start-up the device. The green “ASS” led has to be blinked until an
association.
Inputs
1…6
Inputs
7…10
Programmation
Connector
Outputs
1…2(4)
Power Off
On
----
Off
Button User
Leds