Datasheet

Series JP
Internationally Approved Pushbuttons
C58
Indicators
AccessoriesSupplement
Tactiles
KeylocksRotaries
C
Pushbuttons
Illuminated PB
Slides
Programmable
Rockers
Touch Tilt
Toggles
www.nkkswitches.com
General Specifications
Electrical Capacity (Resistive Load)
Power Level: 10A @ 125/250V AC for JPM models & 16A @ 125/250V AC for JPL models
Other Ratings
Contact Resistance: 20 milliohms maximum
Insulation Resistance: 1,000 megohms minimum @ 500V DC
Dielectric Strength: 2,000V AC minimum between contacts for 1 minute minimum;
4,000V AC minimum between contacts & case for 1 minute minimum
Mechanical Life: 25,000 operations minimum
Electrical Life: 25,000 operations minimum
Nominal Operating Force: JPM Single Pole 3.53N & Double Pole 6.47N
JPL Single Pole 4.51N & Double Pole 9.02 N
Contact Timing: Nonshorting (break before make)
Latchdown: Normal position - flush with barrier; latchdown position - .079” (2.0mm) below normal
Travel: Pretravel .059” (1.5mm); Overtravel .071” (1.8mm); Total Travel .130” (3.3mm)
Materials & Finishes
Housing/Frame & Barrier: Polyamide (UL94V-0) Movable Contacts: Silver alloy
Interior Seal: Polyphenylene sulfide (UL94V-0) Stationary Contacts: Silver alloy plus copper
Case/Base: Melamine (UL94V-0) Terminals: Brass with silver plating
Environmental Data
Operating Temp Range: –10°C through +70°C (+14°F through +158°F)
Humidity: 90 ~ 95% humidity for 96 hours @ 40°C (104°F)
Vibration: 10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
Shock: 50G (490m/s
2
) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
Process Seal: Dust resistant inner seal
Installation
Soldering Time & Temp: Manual Soldering: See Profile A in Supplement section.
Standards & Certifications
Flammability Standards: UL94V-0 for housing/frame, barrier, interior seal, & case/base
TV Ratings for UL: JPM (TV-5) Overload Test @ 125V AC for 50 operations:
Steady State Current (rms) 7.5A; Minimum Inrush Current (peak) 111A
JPM (TV-5) Endurance Test @ 125V AC for 25,000 operations:
Steady State Current (rms) 5A; Minimum Inrush Current (peak) 78A
JPL (TV-8) Overload Test @ 125V AC for 50 operations:
Steady State Current (rms) 12A; Minimum Inrush Current (peak) 163A
JPL (TV-8) Endurance Test @ 125V AC for 25,000 operations:
Steady State Current (rms) 8A; Minimum Inrush Current (peak) 117A
UL: File No. E44145 - Recognized only when ordered with marking on switch.
Add “/U” or “/CUL” before dash in part number to order UL recognized switch.
All JPM models certified at 10A @ 125V AC, TV5 & JPL models at 16A @ 125V AC, TV8.
VDE: License No. 40028887 - Approved only when ordered with marking on switch.
Add “/V” before dash in part number to order VDE approved switch.
All JPM models approved at steady state 5A, inrush 80A, resistive 10A, & motor load 6A all at
250V AC.
License No. 40039784
All JPL models approved at steady state 8A, inrush 128A, resistive 16A, & motor load 8A all at
250V AC.