Datasheet

Series S
Low Capacity Standard Size Toggles
A102
Indicators
AccessoriesSupplement
Tactiles
KeylocksRotaries
Pushbuttons
Illuminated PB
Slides
Programmable
Rockers
Touch Tilt
A
Toggles
www.nkk.com
Notes: Standard Hardware: AT504M Knurled Nut, AT508 Lockwasher, AT527M Backup Hex Nut. See Accessories & Hardware section.
Optional Splashproof Boot Assemblies (only for bat lever models): AT401 & AT4181 boots plus hex nut and o-ring. See Accessories & Hardware section.
S116
Maximum
Panel Thickness:
.158” (4.0mm)
(12.5) Dia
.492
(11.5)
.453
(1.5)
.060
S114 & S116 S116R Black Polyamide Paddle
S114 does not have terminals 3 & 6
(9.0)
.354
(29.0)
1.142
(4.0
)
.157
Keyway
(17.6)
.693
(6.0) Dia
.236
25°
(10.35) Ty
p
.407
(10.0)
.394
(18.0)
.709
(22.9)
.902
(5.5)
.217
(4.0)
.157
(2.3) Dia
.090
(3.8) Typ
.150
(2.0) Dia Typ
.079
M12 P1
(27.8)
1.094
63
25
41
(0.8) Ty
p
.031
(0.3) Typ
.012
DOUBLE POLE WITH SOLDER LUG
* CSA certified only when ordered with
marking on switch (see General Specs)
Toggle Position/Connected Terminals
Electrical Capacity
Model
*Approvals
Pole &
Throw
Down Center Up
Resistive Inductive
Angle
of Throw
AC
125V
AC
250V
DC
30V
AC 125V
PF 0.6
S114 DPST ON 2-1 5-4 NONE OFF
5A 2A 5A 3A 25°
S116 DPDT ON 2-1 5-4 NONE ON 2-3 5-6 5A 2A 5A 3A 25°
S116R DPDT ON 2-1 5-4 NONE ON 2-3 5-6
5A 2A 5A 3A 25°
Throw &
Schematics:
DPST
Keyway
13
4
6
2 5
(COM)
DPDT
Note: Terminal numbers are
actually on the switch
R
––
––
–– ––