Datasheet

Series HS
Standard Size Rotaries
www.nkk.com
G47
Indicators
AccessoriesSupplement Tactiles Keylocks PushbuttonsIlluminated PBSlides Programmable Rockers
Touch
Tilt
Toggles
G
Rotaries
C
L
of Keyway
C
1
1
2
3
4
Knurled Shaft D-flat Shaft
Pole
Number of
Positions
Stopper
Settings
Number of
Terminals *Nonshorting Shorting Nonshorting Shorting Schematic
HS16-1 HS16-1S HS16-1N HS16-1SN 1P 2-11 2, 3, 4 . . . 11 1 COM, 11 LOAD
HS16-2 HS16-2S HS16-2N HS16-2SN 2P 2-11 2, 3, 4 . . . 11 2 COM, 22 LOAD
HS16-3 HS16-3S HS16-3N HS16-3SN 3P 2-11 2, 3, 4 . . . 11 3 COM, 33 LOAD
HS16-4 HS16-4S HS16-4N HS16-4SN 4P 2-11 2, 3, 4 . . . 11 4 COM, 44 LOAD
HS16-5 HS16-5S HS16-5N HS16-5SN 5P 2-11 2, 3, 4 . . . 11 5 COM, 55 LOAD
HS16-6 HS16-6S HS16-6N HS16-6SN 6P 2-11 2, 3, 4 . . . 11 6 COM, 66 LOAD
6 AMP SINGLE POLE/NONSHORTING/45° INDEXING
Schematics
C
L
of Keyway
C
1
1
2
C
L
of Keyway
C
1
1
2
3
Switch is viewed from shaft end and shown in position 1. Terminal numbers are not on switch. Standard Hardware shown on last page of this section.
* Wire harness & cable assemblies offered only in Americas.
1
2
3
C
L
of Keyway
C
1
4
5
6
7
8
9
10
11
12 AMP/SHORTING & NONSHORTING/30° INDEXING
(10.3) Dia
.406
(9.5)
.374
(1.5)
.059
(9.0)
.354
(10.5) Dia
.413
(3.0) Dia
.118
(10.3) Dia
.406
(9.5)
.374
(1.5)
.059
(9.0)
.354
(10.5) Dia
.413
(3.0) Dia
.118
Maximum Effective Panel Thickness
With Locking Ring
.150” (3.8mm)
Without Locking Ring
.189” (4.8mm)
Maximum Effective Panel Thickness
With Locking Ring
.189” (4.8mm)
Without Locking Ring
.228” (5.8mm)
• On each deck of multipole devices common and load terminals
are in the same positions as shown in the schematic above.
Switch is viewed from the shaft end and shown in position 1.
Terminal numbers are on the switch bottom. Stopper positions
are molded on the top of the switch.
Standard Hardware shown on last page of this section.
HS16-2N
HS13X
(34.0) Dia
1.339
(4.8) Typ
.189
Keyway
(10.0)
.394
(10.0)
.394
(16.0)
.630
(0.3)
.012
(5.7) Typ
.224
(40.0)
1.575
(0.7) Typ
.028
M10 P0.75
(6.0) Dia
.236
4
5
°
T
y
p
2
1
3
4
COM
(2.6) Dia Typ
.102
C
O
M
1
1
1
0
9
8
7
6
5
4
3
2
1
(6.24) Typ
.246
(2.6) Dia Typ
.102
(8.0) Typ
.315
Keyway
M10 P0.75
(6.0) Dia
.236
(0.84) Typ
.033
(7.0) Max
.276
(74.5)
2.933
(64.5)
2.539
(54.5)
2.146
(44.5)
1.752
(34.5)
1.358
(24.5)
.965
(10.0)
.394
(14.0)
.551
(15.0)
.591
(65.0)
2.559
15°
30°
(4.4)
.173
(55.0)
2.165
Round
Shaft
D-flat
Shaft
Number of
Positions
Stopper
Settings
Number of
Terminals *
Load
Terminals
HS13X HS13X-D 2 Fixed 1 COM, 2 LOAD 1 & 2
HS13Y HS13Y-D 3 Fixed 1 COM, 3 LOAD 1, 2, & 3
HS13Z HS13Z-D 4 Fixed 1 COM, 4 LOAD 1, 2, 3, & 4
HS13X HS13Y HS13Z
Switch is viewed from shaft end and shown in position 1. Terminal numbers are not on switch. Standard Hardware shown on last page of this section.
* Wire harness & cable assemblies offered only in Americas.