miniCool NB 140 Operating Instructions 207.5027.
Please read these operating instructions carefully before putting the refrigeration unit into operation. If you later sell or dispose of it, please ensure that the new owner receives these operating instructions. Please follow the installation details below carefully Guarantee is valid for products installed as described only. (See chapter 4.1) Thank you for choosing our appliance. We are sure it will provide you with trouble-free use.
CONTENT S 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Unpacking View of the appliance Cleaning Positioning the appliance 4.1. Installation instruction Using the appliance 5.1. Temperature regulation Useful suggestions Defrosting, cleaning and maintenance Reversing the door hang Replacing the decorative door panel Customer service Putting into operation, technical data 11.1.
1. Unpacking After removal from the cardboard packaging, make sure the appliance is not damaged. If you find damage to the appliance resulting from transport, report it immediately to the transportation firm. 2. View of the appliance 1 3 2 NB 140 Figure 1. 1. Door 3. Evaporator 2. Thermostat knob IN CASE IF YOUR REFRIGERATOR IS EQUIPPED WITH LOCK, MANUFACTURER DO NOT ACCEPT LIABILITY FOR LOSS OR DAMAGE OF KEYS. HOWEVER WE WOULD BE HAPPY TO SUPPLY A COMPLETE LOCK AND KEY REPLACEMENT.
3. Cleaning Clean the refrigerator thoroughly at intervals, as necessary. Remove the shelves; these, the cabinet interior and the door should be washed with a warm solution of sodium bi-carbonate. Finally wipe over with a cloth rinsed in warm water only, and dry with a clean cloth. Do not wash any plastic parts in water that is more than hand warm, and do not expose them to dry heat. The outside of the cabinet should be wiped down regularly with a clean, damp cloth.
3. Ventilation must be provided as shown in alternatives A, B, C or D (fig 2-3) 4. The ventilation duct must at least measure 105mm x the width of the refrigerator 5. Only the entire cooling unit must project into the duct as shown 6. Air passing through the duct must not be preheated by any source of heat 7. Ventilation grills, if used, must have openings of at least 200cm2 each During installation, please ensure the mains plug is accessible at all times. 5.
6. Useful suggestion Do not overfill the appliance. It is advisable to leave some space between the products in the cabinet to ensure efficient and even cooling. If the shelves are packed too tightly there may be unacceptable temperature variations. 7. Defrosting, cleaning and maintenance Frost will gradually form on the cooling surfaces and it must not be allowed to become too thick since it acts as an insulator and interferes with the cooling.
9. Replacing the decorative door panel, Fig. 7-9 Remove the two screws (1) from the upper hinge of the door. Pull the door together with the hinge away from the housing and up off the lower hinge bolt (2-3). Remove screws (4) and pull off the frame edge (5). Slide the decorative panel (6) out of the door frame and insert the new panel (7), so that the upper edge of the panel runs exactly parallel to the upper edge of the frame.
If after checking all the above points, the refrigerator is still not working satisfactorily, contact your nearest service engineer. State the problem, model, productand serial-number. (Details of the model, product- and serialnumber are to be found on the data label in the top left of the inside compartment.) This refrigerator is equipped with overheating protection. An authorised service technician can check whether this has been triggered or not.
11.1 Connecting to electrical mains The appliance may only be operated from nominal voltage mains as shown on the data plate. The appliance mains plug may be connected to a mains socket earthed in accordance with regulations. Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. The manufacturer declines any liability should these safety measures not be observed.
12. Environmental protection information The appliance does not contain any CFCs/HCFCs. Ammonia (natural hydrogen and nitrogen compound) is used as a refrigerating agent in the refrigeration unit. The ozone-friendly cyclopentane is activated as a motive agent for the PU foam insulation. Sodium chromate is used for corrosion protection (less than 2 weight % of the coolant). 13. Recycling After unpacking the appliance, the packing materials should be delivered to a local collection site.