INITIALIZATION 
5 
When not using PoE for power and data, use an Altronix power supply to power Nokē 
Screen. Data will need to be provided via WiFi. First, connect the power supply wire (12V-
24V DC) and both the ground (GND) and earth ground (ESD GND) wires to their relay push 
pin connectors on the relay board, and then insert the relay board into the control board. 
(Use only 18-gauge, 2 conductor wire.) 
Connect wires coming from the entry point (or gate) to the common (COM) and either 
normally open (NO) or normally closed (NC) pins on the power board. Extra connectors are 
provided on the power board to connect and control additional electrical locks to the Nokē 
Screen. 
Power Board 
(Close Up) 
Nokē Screen 
Control Board 
Note: Gate wiring can 
be installed into NC_1, 
depending upon the type 
of entry being used. 
+24v DC 
Ground 
Entry 
Point 