Installation Manual

Nokia RoofTop™ Wireless Router Installation Guide 39
APPENDIX D Required Minimum Working
Distances for Antennas
The installer must ensure, that the installation is such, that a minimum
separation distance, as indicated in table 1, from persons is guaranteed in
order to comply with exposure guidelines. When co-locating installations
of dissimilar type, the installer must use the MPE distance for whichever
installation has the highest MPE requirement.
MPE distance (cm) for number
of co-located antennas
Installation Min.
Feeder
Cable
Length (ft)
Max. EIRP at
Individual
Antenna
(dBm)
12345 6
8dBiomni 0
8dBipanel 0
10 dBi omni 50
10 dBi sector 50
34 15 20 25 30 35 35
12 dBi sector 50
8 dBi omni with amplifier 0
36 20 30 35 40 40 45
15 dBi panel 0 41 30 45 55 65 75 80
17 dBi panel 0 43 35 60 70 80 90 100
Table 1. MPE safety distances