PAMS Technical Documentation NPM–9 Series Transceivers Service Tools Issue 1 02/2002 Nokia Corporation
NPM–9 Service Tools PAMS Technical Documentation CONTENTS JBV-1 Docking Station and MJF-6 Adapter . . . . . . . . . . . . . . . . . . . . . . . RF-Coubler CPL-4: measured losses . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of JBV-1 and MJF-6 together . . . . . . . . . . . . . . . . . . . . . . . . . . . . MJS-46 Module Jig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PAMS Technical Documentation NPM–9 Service Tools Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of FLS-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCS-1 Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PCS-1 . . . . . . . . . . . . . . .
NPM–9 Service Tools PAMS Technical Documentation JBV-1 Docking Station and MJF-6 Adapter The JBV-1 Docking Station has been designed for calibration and software update use. The MJF-6 Docking Station Adapter makes signal connections to the phone. JBV-1 and MJF-6 are used as one unit.
NPM–9 Service Tools PAMS Technical Documentation RF-Coubler CPL-4: measured losses Rohde & Schwarz CMU 200 Phoenix Service Software Estimated Output levels: EGSM 32 dBm and GSM1800 29dBm EGSM Ch GSM1800 Loss Ch TX RX 975 6.1 dB 5 dB 31 5.1 dB 124 4.4 dB Loss TX RX 512 3.7 dB 3 dB 6 dB 700 3.1 dB 4 dB 6 dB 885 3.
NPM–9 Service Tools PAMS Technical Documentation MJS-46 Module Jig The MJS-46 Module Jig is used for testing of UI/system/RF-module*. Product Code MJS-46 Module Jig: 0770316 NOTE: This jig comes with UI module 9490306 for NHM-7. To be able to service NPM-9, you need UI module 0201817 for APAC and 0201868 for Europe. When installing the UI module, you need to bend the 2 UI module fixings apart (on both sides of the LCD). View of MJS-46 *Note: Page 6 The nominal supply voltage for MJS-46 is +8.0 V.
NPM–9 Service Tools PAMS Technical Documentation MJS-47 Soldering Jig The Soldering Jig MJS-47 is used for soldering and as a rework jig for system module.
NPM–9 Service Tools PAMS Technical Documentation LRK-1 Rework Kit The LRK-1 Rework Kit is used for PA Chip (LGA type component) rework and includes Rework Jig MJS-54, SES-1 Stencil and SPS-1 Soldering Paste Spreader. The sales pack includes: MJS-54 Rework Jig: SES-1 Stencil: SPS-1 Soldering Paste Spreader: Note: Not included in sales package.
NPM–9 Service Tools PAMS Technical Documentation FPS-8 Flash Prommer (Sales Pack) The Flash Prommer FPS-8 is used with e.g. FLA-18 and JBV-1. Power is supplied to FPS-8 from the Universal Power Supply.
NPM–9 Service Tools PAMS Technical Documentation FPS-8C Parallel Flash Prommer (Sales Pack) - optional The Parallel Flash Prommer FPS-8C is used with MJF-6 and JBV-1. Flash programming can be done to maximum of 8 phones parallel. FPS-8C consists of eight SF11C programming cards. SF11C card is functionally identical to FPS-8.
NPM–9 Service Tools PAMS Technical Documentation ACF-8 Universal Power Supply ACF-8 Universal Power Supply is used to power FPS-8. ACF-8 has 6 V DC and 2.1 A output.
NPM–9 Service Tools PAMS Technical Documentation FLA-18 POS (Point Of Sale) Flash Loading Adapter The POS Flash Loading Adapter FLA-18 is used in place of the phone’s normal battery during service, to supply a controlled operating voltage.
NPM–9 Service Tools PAMS Technical Documentation FLC-2 DC Cable The FLC-2 is used to supply a controlled operating voltage.
NPM–9 Service Tools PAMS Technical Documentation AXS-4 Service Cable The AXS-4 D9-D9 Service Cable is used to connect two 9 pin D connectors e.g. between PC and FPS-8. Cable length is 2 meters.
NPM–9 Service Tools PAMS Technical Documentation XCS-1 Service Cable The XCS-1 Service Cable is used to connect FLS-4 to FLA-18.
NPM–9 Service Tools PAMS Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whithout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
NPM–9 Service Tools PAMS Technical Documentation FLS-4 POS (Point Of Sale) Flash Device (Sales Pack) FLS-4 is a dongle and flash device incorporated into one package, developed specifically for POS use.
NPM–9 Service Tools PAMS Technical Documentation PCS-1 Power Cable The PCS-1 Power Cable (DC) is used to connect e.g. JBV-1 to FPS-8.
NPM–9 Service Tools PAMS Technical Documentation XRF-1 RF Cable RF cable XRF-1 is used to connect e.g. Module Jig MJS-46 to RF measurement equipment..
NPM–9 Service Tools PAMS Technical Documentation DAU-9S MBUS Cable The MBUS Cable DAU-9S has a modular connector, and is used with between PC’s serial port and e.g. Module Jig MJS-46.
NPM–9 Service Tools PAMS Technical Documentation SCB-3 DC Cable The DC Cable SCB-3 is used to connect e.g. JBV-1 to the phone.
NPM–9 Service Tools PAMS Technical Documentation XCS-4 Modular Cable XCS-4 is a shielded cable (one specially shielded conductor) modular cable for flashing and service purposes.
NPM–9 Service Tools PAMS Technical Documentation Printer Cable This cable is used to connect the PC to FPS-8.
NPM–9 Service Tools PAMS Technical Documentation This page intentionally left blank.