Specification Sheet

6505 Gayhart Street, Commerce, CA 90040
TEL 323.767.2600 | www.noralighting.com | e-mail: nora@noralighting.com
© 2020 Nora Lighting, Inc. All rights reserved. Specifications subject to change without notice.
041020P1
Type
Project
Catalog No.
Notes
PRODUCT DESCRIPTION
New construction housing for use in insulated ceilings
can be in direct contact with insulation**. Air-tight
construction provides energy savings by reducing the flow
of air through the ceiling. Patented design allows for easy,
tool-less removal of the driver.
FEATURES
· IC rated for direct contact with insulation**
· Quick connect provided for electrical connection to the
LED reector
· ASTM E283 for Air-Tight
· Patented driver assembly
SPECIFICATION
Housing: 0.040” Aluminum housing with patented
driver assembly, allows for driver to slide out without
tools. Housing can be installed in 1/2” ceiling thickness, an
extension collar is available for ceiling thickness up to 2”,
must specify NIO-4EXTC2. Housing allows for access through
top plate, for driver maintenance/installation above ceiling.
Air Flow Restriction: Meets requirments of Air-Tight (AT)
<2CFM (cubic feet per minute) in accordance with ASTM-
283 Air-Tight requirements.
Clearance**: “IC” Insulated ceiling housings are direct
contact rated. Not to be used in direct contact with spray
foam insulation.
Bar Hangers: Two 13-3/4” to 24-1/2” adjustable bar
hangers with captive nails are included on housing. Bar
hanger brackets are parallel to junction box, but can
be repositioned 90˚ perpendicular to junction box if
desired. “L”-shaped bar hanger foot to align to bottom of
construction joist. A T-bar notch allows for easy installation
in a suspended ceiling.
Junction Box: Pre-wired 25 cubic inch 0.064” thick
galvanized steel, with seven 1/2” knockouts, four Romex®
pryouts, and snap on covers. All leads are #18AWG wire,
the ground wire is connected to the bottom, and quick
connectors are supplied on all leads. Through branch
circuit wiring, (4-in, 4-out). Access above ceiling required.
ELECTRICAL
Voltage: 120/277V
Power Factor: >0.90
Operating Temp.:
NHIOICD-415: 0°-40°C (LE4) or 0°-25°C (LUPEQ)
NHIOICD-420: 0°-30°C
NHIOICD-425: 0°-25°C
Wattage: 20W, 24W to 28W (must specify)
Dimming: Triac, ELV, 0-10V or EcoSystem (must specify)
Click Here or check complete dimmer list at
www.NoraLighting.com in the “Compatibility” page under
“Resources” tab
COMPATIBLE REFLECTORS
CATALOG NO. DESCRIPTION
NIO-4RC 4" Round Cone Regress
NIO-4SC 4" Square Cone Regress
NIO-4RG 4" Round Adj. Surface Gimbal
NIO-4SG 4" Square Adj. Surface Gimbal
NIO-4RD 4" Round Adj. Deep Regress
NIO-4SD 4" Square Adj. Deep Regress
NIO-4RNDC 4" Round Deep Reflector
NIO-4SNDC 4" Square Deep Reflector
NIO-4RPH 4" Round Pinhole
NIO-4RPHA 4” Round Adj. Pinhole
NIO-4RSL 4" Round Adj. Slot Aperture
NIO-4RNB 4" Round Bullnose
NIO-4SNB 4" Square Bullnose
NIO-4SNDSQ 4” Square Reflector / Square Aperture
(1500 & 2000lm only)
NIO-4SDSQ 4" Square Adjustable / Square Aperture
NIO-4SW 4" Square Wall Wash (1500 & 2000lm only)
NIO-4RTLA 4” Round Trimless Adj. Reflector
NIO-4RTLNDC 4” Round Trimless Reflector
Emergency: Housing can be specified with connections
for emergency battery installation. Requires top access.
Must specify battery with remote test switch separately,
NEPK-07LEDUNV. Note: Emergency is not compatible with
chicago plenum housings.
LABELS AND LISTINGS
· cULus Listed for Damp Location
(Wet Location when used with compatible reector)
· 5-Year Limited Warranty
· RoHS Compliant
· FCC compliant
· Patent #D824567S
· Meets or exceeds ASTM-283 Air-Tight requirements
RoHS
COMPLIANT
WARRANTY
LIMITED
YEAR
5
Housing Type / Lumens / Wattage Driver / Dimming Optional Emergency
NHIOICD-415 = IC Air-Tight, 1500lm / 20W LE4 = 120/277V input; Triac / ELV / 0-10V dimming
LUPEQ = 120/277V input; Lutron Hi-lume Premier
0.1% EcoSystem with Soft-On, Fade-to-Black
LUPEQ1 = 120/277V input; Lutron Hi-lume
1% EcoSystem with Soft-On, Fade-to-Black
/PEM = Pre-Wired for
Remote Emergency
NHIOICD-420 = IC Air-Tight, 2000lm / 24W
NHIOICD-425 = IC Air-Tight, 2500lm / 28W
LE4 = 120/277V input; Triac / ELV / 0-10V dimming
/PEM = Pre-Wired for
Remote Emergency
NHIOICDCP-415 = Chicago Plenum, 1500lm / 20W LE4 = 120/277V input; Triac / ELV / 0-10V dimming
LUPEQ = 120/277V input; Lutron Hi-lume Premier
0.1% EcoSystem with Soft-On, Fade-to-Black
LUPEQ1 = 120/277V input; Lutron Hi-lume
1% EcoSystem with Soft-On, Fade-to-Black
NHIOICDCP-420 = Chicago Plenum, 2000lm / 24W
NHIOICDCP-425 = Chicago Plenum, 2500lm / 28W
LE4 = 120/277V input; Triac / ELV / 0-10V dimming
4” Iolite ICAT High Lumen New Construction Housing - Compatible with NIO-4 reflectors
Description
NEPK-07LEDUNV = Remote Emergency Battery w/Test Switch
NIO-4EXTC2 = Ceiling Extension Collar up to 2"
Optional Accessories
Example: NHIOICD-420LE4 = 4" Iolite ICAT High Lumen New Construction Housing, 2000lm / 24W, 120-277V input; Triac / ELV / 0-10V dimming
NHIOICD-415 / NHIOICD-420 / NHIOICD-425
NHIOICDCP-415 / NHIOICDCP-420 / NHIOICDCP-425
4" Iolite IC Air-Tight High Lumen New Construction Housing
Source: 20W to 28W LED
1500lm to 2500lm
PRODUCT IMAGES AND DIMENSIONS
10-1/2"
5-5/8"
16-7/8"
PATENT
No. D824567S
4-5/16”
Ceiling Cut-Out

Summary of content (1 pages)