Specification Sheet

6505 Gayhart Street, Commerce, CA 90040
TEL 323.767.2600 | www.noralighting.com | e-mail: nora@noralighting.com
© 2021 Nora Lighting, Inc. All rights reserved. Specifications subject to change without notice.
110821P2
Type
Project
Catalog No.
Notes
PHOTOMETRICS
MAY LED Track Head
Test Information
Test Number: NTT11022R2
Part Number: NTE-860L927M10
Beam Spread: 34° Narrow Flood
Lumens: 753lm
Wattage: 9.3W
Efficacy: 81lpw
CCT / CRI: 2700K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 629 83.6
0-40 697 92.6
0-60 732 97.3
0-90 743 98.7
90-180 10 1.3
0-180 753 100
Candela Table
Vertical
Angles
Candela
0 1788
5 1706
15 1066
25 394
35 101
45 27
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 112fc 2'-6"
6' 49.7fc 3'-8"
8' 27.9fc 4'-11"
10' 17.9fc 6'-2"
12' 12.4fc 7'-5"
10° 30°
50°
1788
1341
894
447
70°
Polar Curve
Test Information
Test Number: NTT11023R1
Part Number: NTE-860L930M10
Beam Spread: 34° Narrow Flood
Lumens: 801lm
Wattage: 9.42W
Efficacy: 85lpw
CCT / CRI: 3000K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 675 84.3
0-40 746 93.2
0-60 781 97.5
0-90 790 98.7
90-180 11 1.3
0-180 801 100
Candela Table
Vertical
Angles
Candela
0 1904
5 1795
15 1133
25 440
35 105
45 226
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 119fc 2'-6"
6' 52.9fc 3'-8"
8' 29.8fc 5'
10' 19fc 6'-2"
12' 13.2fc 7'-6"
10° 30°
50°
1904
1428
952
476
70°
Polar Curve
Test Information
Test Number: NTT11024R2
Part Number: NTE-860L935M10
Beam Spread: 34° Narrow Flood
Lumens: 848lm
Wattage: 9.47W
Efficacy: 90lpw
CCT / CRI: 3500K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 710 83.7
0-40 787 92.8
0-60 826 97.4
0-90 837 98.6
90-180 12 1.4
0-180 848 100
Candela Table
Vertical
Angles
Candela
0 2002
5 1904
15 1200
25 454
35 116
45 29
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 125fc 2'-6"
6' 55.6fc 3'-8"
8' 31.3fc 5'
10' 20fc 6'-2"
12' 13.9fc 7'-6"
10° 30°
50°
2002
1502
1001
501
70°
Polar Curve
Test Information
Test Number: NTT11025R2
Part Number: NTE-860L940M10
Beam Spread: 34° Narrow Flood
Lumens: 866lm
Wattage: 9.58W
Efficacy: 90lpw
CCT / CRI: 4000K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 725 83.7
0-40 803 92.7
0-60 842 97.2
0-90 853 98.5
90-180 13 1.5
0-180 866 100
Candela Table
Vertical
Angles
Candela
0 2023
5 1927
15 1220
25 470
35 117
45 29
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 126fc 2'-6"
6' 56.2fc 3'-10"
8' 31.6fc 5'
10' 20.2fc 6'-4"
12' 14fc 7'-6"
10° 30°
50°
2023
1518
1012
506
70°
Polar Curve
Test Information
Test Number: NTT11058R1
Part Number: NTE-860L9CDM10
Beam Spread: 35° Narrow Flood
Lumens: 651lm
Wattage: 9.72W
Efficacy: 67lpw
CCT / CRI: 2900K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.6
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 550 84.4
0-40 604 92.7
0-60 539 98.1
0-90 650 99.8
90-180 1 0.2
0-180 651 100
Candela Table
Vertical
Angles
Candela
0 1487
5 1385
15 898
25 365
35 76
45 24
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 93fc 2'-7"
6' 41.3fc 3'-10"
8' 23.2fc 5'-1"
10' 14.9fc 6'-5"
12' 10.3fc 7'-8"
10° 30°
50°
1488
1116
744
372
70°
Polar Curve