PHOTOMETRICS
MAY LED Track Head
Test Information
Test Number: NTT11022R1
Part Number: NTE-860L927M10
Beam Spread: 35° Narrow Flood
Lumens: 753lm
Wattage: 9.3W
Efficacy: 81lpw
CCT / CRI: 2700K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 629 83.6
0-40 697 92.6
0-60 732 97.3
0-90 743 98.7
90-180 10 1.3
0-180 753 100
Candela Table
Vertical
Angles
Candela
0 1788
5 1706
15 1066
25 394
35 101
45 27
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 124fc 2'-6"
6' 55.3fc 3'-8"
8' 31.1fc 4'-11"
10' 19.9fc 6'-2"
12' 13.8fc 7'-5"
10° 30°
50°
1788
1341
894
447
70°
Polar Curve
Test Information
Test Number: NTT11023R1
Part Number: NTE-860L930M10
Beam Spread: 35° Narrow Flood
Lumens: 801lm
Wattage: 9.42W
Efficacy: 85lpw
CCT / CRI: 3000K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 675 84.3
0-40 746 93.2
0-60 781 97.5
0-90 790 98.7
90-180 11 1.3
0-180 801 100
Candela Table
Vertical
Angles
Candela
0 1904
5 1795
15 1133
25 440
35 105
45 226
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 132fc 2'-6"
6' 58.8fc 3'-8"
8' 33.1fc 5'
10' 21.2fc 6'-2"
12' 14.7fc 7'-6"
10° 30°
50°
1904
1428
952
476
70°
Polar Curve
Test Information
Test Number: NTT11024R1
Part Number: NTE-860L935M10
Beam Spread: 35° Narrow Flood
Lumens: 835lm
Wattage: 9.38W
Efficacy: 89lpw
CCT / CRI: 3500K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 699 83.7
0-40 775 92.8
0-60 813 97.4
0-90 824 98.6
90-180 11 1.4
0-180 835 100
Candela Table
Vertical
Angles
Candela
0 1971
5 1875
15 1181
25 500
35 114
45 29
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 137fc 2'-6"
6' 60.7fc 3'-8"
8' 34.1fc 5'
10' 21.9fc 6'-2"
12' 15.2fc 7'-6"
10° 30°
50°
1971
1478
986
493
70°
Polar Curve
Test Information
Test Number: NTT11023R1
Part Number: NTE-860L940M10
Beam Spread: 35° Narrow Flood
Lumens: 811lm
Wattage: 9.6W
Efficacy: 84lpw
CCT / CRI: 4000K / 90 CRI
Spacing Criteria (0°-180°): 0.58
Spacing Criteria (90°-270°): 0.58
Zonal Lumen Summary
Zone Lumens
%
Luminaire
0-30 678 83.7
0-40 752 92.7
0-60 788 97.2
0-90 798 98.5
90-180 12 1.5
0-180 914 100
Candela Table
Vertical
Angles
Candela
0 1894
5 1804
15 1143
25 440
35 110
45 27
Illuminance at a Distance
Distance from
Luminaire
FC at Nadir Beam Diameter
4' 133fc 2'-6"
6' 59.3fc 3'-10"
8' 33.4fc 5'
10' 21.4fc 6'-4"
12' 14.8fc 7'-6"
10° 30°
50°
1894
1421
947
474
70°
Polar Curve