Manual

4
3 Installation
3.1 CANbus Interface Installation
1. Securely mount the control module (E01) on the center boom at the rear of the sprayer.
2. Tee the CANbus interface cable (C40) in to the Case “Application” CANbus. The
“Application” CANbus is a 3 pin Deutsch connector located on the center section of the
boom at the rear of the sprayer.
3. Connect the Deutsch plug on cable C40 to the end of the control module with only one
Deutsch connector.
4. Connect the power cable (C30) to one of the two CANbus connectors on the control
module. Connect the 2 pin DT connector on C30 to an appropriate power source.
5. Connect cable C41 to the other CANbus connector and route the cable to the Valve
Module.
Figure 1: CANbus Interface Installation