Instruction Manual

17
7 Electrical Installation
1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where it
will be clearly visible and within easy reach of the operator.
A good spot to mount the UC4.5 control panel is on the right hand side of the cab to the
Roll Over Protection Bar. Four pilot holes for the screws provided need to be drilled to
facilitate the control panel mounting.
Another option is to purchase an adapter for the flexible panel mount that has a 3/8" NC
threaded stud on the end to bolt through an existing mount. These are available at your
local outdoor store as a RAM mount part number RAM-B-236. (See http://www.ram-
mount.com/)
Figure 17: Cable Configurations: C10, C11 and C30
2. Connect the UC4.5 power cable (C10) to the UC4.5 Control Panel in the cab. Ensure that
both plugs (P16 and P4) are connected to the panel. Cable tie C10 to the RAM mount to
help provide strain relief.
3. Connect P6 on C30 to P6A of C10 using a 2-way coupler (E12). Connect the 3-pin AMP
connector C30 to an auxiliary power connection in the sprayer cab. If an appropriate
connector cannot be found, it may be necessary to cut off the connector and splice into the
existing wiring.
Ensure the UC4.5 Control Panel’s power is OFF for the remaining installation.
(Bottom of switch pressed IN).
4. Route the P12/P6 of C10 out of the cab.
5. Connect P12/P6 to R12/R6 of the extension cable (C11) outside of the cab.