Manual

19
7.2 Valve Module
1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin
Deutsch (CANbus) connectors towards the “P” and “T” ports with the label facing up.
Figure 16: Valve Module
2. Verify the valve coil connectors are oriented vertically (Figure 17).
Figure 17: Align Coils
3. Place the valve module between the valve coils. Slide a valve mounting bracket over the
connectors of the valve module and the valve coil connectors. This may require flexing the
plastic bracket slightly (Figure 18).
4. Ensure the bracket is pushed over the connectors far enough to allow the clips to engage
behind the valve connectors.
Output Numbe
r
Normal Function
1
Left Up
2
Left Down
3
Right Up
4
Right Down
5
Main Up
6
Main Down
7
Roll CW
8
Roll CCW