Datasheet
Data sheet for General Purpose Toroidal Transformers – 30VA Economy Series
Dual Primary winding for connection in series or
parallel only
Input voltage : 115V or 230V +/-10% 50/60 Hz
Dc resistance : 2x 53Ohms +/-20% @ 20
o
C
Magnetising current : 3,7mA @ primary 230V 50Hz
7,4mA @ primary 115V 50Hz
All leads UL1569/UL1015 / 105
o
C
Primary leads Double insulated with Insulation Class B
tubes, minimum length 20mm
Lead length Tolerance +/-10mm
all lead ends 6mm tinned
All Leads exit at the outer top edge,
Iron loss : 0,4 Watts
Copper loss : 5,8Watts
Efficiency : 83% Typical
Calculated Temperature rise : 52
o
C
( In open environment )
Maximum rated ambient : 40
o
C
Winding wire : Class H (180
o
C)
Insulation System : Class B (130
o
C)
Leads insulation : Class A (105
o
C)
Degrees of protection : IP00
!"
Diameter : 67mm
Inner Diameter : 22mm
Height : 31mm
Weight : 0,5kg
#$
1 x Metal washer 50mm
2 x Rubber pad 50mm
1 x M5 Screw, nut and washer
%%
Designed and manufactured in accordance with : EN61558-1 / EN61558-1/A1 / EN61558-2-4 or EN61558-2-6
UL recognised under family approval E115159 and E20244 to UL1411,UL60601-1,UL1950.
#&
Model number TI-xxxxxxxx ta40/A IP00
Prim. 2 x 115V 50Hz Fuse XXAT E115159
Thermal fuse 125
o
C E115159
Sec. 2 x rated voltage and rated current Amp Fuse XXAT Z125
Art. No.: ES0030/XX
Ordering Code Art. No.
Load
voltage
No load
voltage
Rated
current
Secondary
wire gauge
Secondary DC
resistance
Ohoms @ 20
o
C
TI-044201-ME-ES ES0030/6 2 x 6V 2 x 7,1V 2 x 2,5A AWG18 2 x 0,23
TI-044202-ME-ES ES0030/9 2 x 9V 2 x 10,6V 2 x 1,7A AWG20 2 x 0,44
TI-044203-ME-ES ES0030/12 2 x 12V 2 x 14,3V 2 x 1,25A
AWG22 2 x 0,92
TI-044204-ME-ES ES0030/15 2 x 15V 2 x 17,8V 2 x 1A AWG22 2 x 1,42
TI-044205-ME-ES ES0030/18 2 x 18V 2 x 21,4V 2 x 0,83A
AWG22 2 x 2,1
TI-044206-ME-ES ES0030/25 2 x 25V 2 x 29,6V 2 x 0,6A AWG22 2 x 3,7
OR
Sec V (15VA)
Sec V (15VA)
115V
0V
0V
115V
0V
0V
Primary
Secondary
Thermal fuse 125
o
C
Thermal fuse 125
o
C
%' ()
$&' ()
*' ()
$' ()
+$$*
)
,$
(