Owner's manual

4 Frequency inverters - settings and control elements
BU 0090 GB 37
4.1.3 Information parameters
Parameter Setting value / Description / Note Comments
P740 ... - 01
... - 06
Process data bus In
SK 300E, SK 700E, SK 750E
0000 ... FFFF (hex)
Displays the actual control word and the setpoints.
... - 01 = Control word
... - 02 = Setpoint 1 (P546)
... - 03 = Setpoint 1 High byte
... - 04 = Setpoint 2 (P547)
... - 05 = Setpoint 3 (P548)
... - 06 = Bus I/O In Bits (P480)
P740 ... - 01
... - 13
Process data bus In
SK 500E
... - 01 = Control word...
Control word, source from P509.
... - 02 = Setpoint 1
... - 03 = Setpoint 2
... - 04 = Setpoint 3
Setpoint data from main
setpoint P510 - 01.
... - 05 = Bus I/O Out Bits (P480)
The displayed value depicts
all Bus In bit sources linked
with OR.
... - 06 = Parameter data In 1
... - 07 = Parameter data In 2
... - 08 = Parameter data In 3
... - 09 = Parameter data In 4
... - 10 = Parameter data In 5
Data during parameter
transfer.
0000 ... FFFF (hex) This parameter informs
about the actual control
word and the setpoints that
are transferred via the bus
systems.
... - 11 = Setpoint 1
... - 12 = Setpoint 2
... - 13 = Setpoint 3
Setpoint data from auxiliary
setpoint
P510 -02.
P741 ... - 01
... - 06
Process data bus Out
SK 300E, SK 700E, SK 750E
0000 ... FFFF (hex)
Displays the actual status word and actual values.
... - 01 = Status word
... - 02 = Actual value 1 (P543)
... - 03 = Actual value 1 High byte
... - 04 = Actual value 2 (P544)
... - 05 = Actual value 3 (P545)
... - 06 = Bus I/O In Bits (P481)
P741 ... - 01
... - 13
Process data bus Out
SK 500E
... - 01 = Status word
Status word, source from P509.
... - 02 = Actual value 1 (P543)
... - 03 = Actual value 2 (P544)
... - 04 = Actual value 3 (P545)
... - 05 = Bus I/O Out Bits (P481)
The displayed value depicts
all Bus In bit sources linked
with OR.
... - 06 = Parameter data Out 1
... - 07 = Parameter data Out 2
... - 08 = Parameter data Out 3
... - 09 = Parameter data Out 4
... - 10 = Parameter data Out 5
Data during parameter
transfer.
0000 ... FFFF (hex) This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.
... - 11 = Master function actual value 1
... - 12 = Master function actual value 2
... - 13 = Master function actual value 3
Actual value of master
function
P502/P503.