Owner's manual

NORDAC SK DA-130E
BU 0130 DE techn. changes reserved 11
4 Electrical connection
Power cable: Connection to the mains should be carried out with a cable suitable for the local
conditions and with a sufficient wire gauge (max. 4mm
2
).
Aux. Voltage: 24V I/O: 2x 3 phase plug with tension-spring terminals of 2.5mm
2
: voltage supply
and output
Aux. Voltage: 24V bus: 2x 3 phase plug with tension-spring terminals of 2.5mm
2
: voltage supply
and output
Cable entry: 3 x M25 and 2 x M16 are available. The motor startup is realised with a system connector
Harting HAN 10E.
Power output
[Line Out]
Power feed
[Line In]
Functional module
Analogue output 24V
Auxiliary voltage
[24V I/O]
(equal to 24V_Ext.)
Auxiliary voltage
[24V Bus]
In preparation:
functional module
Auxiliary voltage
[24V_Ext.]
(equal to 24V I/O)