Owner's manual

NORDAC SK DA-130E
12 techn. amendments reserved BU 0130 DE
4.1 Terminals
Terminal Function Data
Power stack
(Line potential)
Line In
L1, L2, L3
Voltage supply 4mm
2
, 380...480V, 50...60Hz, 32 A max.
Line Out
L1, L2, L3
Power output 4mm
2
, 380...480V, 50...60Hz, 32 A max.
PE Protective earthing conductor 4mm
2
24V-level I/O
(Equal to 24V
Ext.)
Line In
24V, GND, PE
24V I/O-supply 3x 2.5mm
2
, 15...30V, max. 6 A
Line Out
24V, GND, PE
24V I/O- output 3x 2.5mm
2
, 15...30V, max. 6 A
24V-level bus
Line In
24V, GND, PE
24V Bus supply 3x 2.5mm
2
, 15...30V, max. 6 A
Line Out
24V, GND, PE
24V Bus output 3x 2.5mm
2
, 15...30V, max. 6 A