3.1 Diagnostic LEDs on the motor starter
The motor starter generates operating status messages. These messages (warnings, errors, switching sta-
tuses, measurement data) can be displayed with parameterisation tools (e.g. ParameterBox - see Section
3.2) (Parameter group P7xx).
To a limited extent, the messages are also indicated via the diagnostic and status LEDs.
Diagnostic LEDs
LED
Name
Colour
Description
Signal status
Meaning
DS dual
red/green
Device status off Starter not ready for operation,
no control voltage
green on Starter is switched on (running)
green
flashing
0.5 Hz Starter is ready for switch-on
4 Hz Starter is in switch-on block
red/green 4 Hz Warning
Alternating 0.5 Hz Starter is not ready for switch-on
24V supply available, but no
mains voltage
red
flashing
Error, flashing frequency → Error number
AS-I dual
AS-i status
off No voltage to the AS-I module (PWR)
red/green green Normal operation
red No exchange of data
Slave Address = 0 / Slave not in LPS /
Slave with incorrect IO/ID /
Master in
STOP mode / Reset active
alternately
flashing
red / yellow
2 Hz no exchange of data
à Slave address = 0
alternately
flashing
red / green
2 Hz
Peripheral error
red
flashing
2 Hz
EMC / Hardware error
PBR green
Status PBR
off
No cyclic process data communication
active
green Normal operation, cyclic process data communi-
cation in operation
NOTE
If there is active RS232 communication to a PC (NORD CON) or connected
control boxes, the device status cannot be displayed. In this case the LED indi-
cates that there is communication and in genera
l is therefore always "green".
In this case the red LED is switched off. If the current potentiometer is adjusted,
the green LED may also flicker due to the operating principle.