2.7.2 Motor cable (U, V, W, earth)
The motor cable may have a total length of up to 100m if this is a standard cable. If a screened motor
cable is used, or if the cable is laid in a well earthed metal conduit, the total length should not exceed
20m. In order to comply with interference suppression class C2, a total length of 5m must not be
exceeded.
Note: Please also note Section 9.4 EMC limit
value classes.
Note: For multiple motor use the total cable length
consists of the sum of the individual cable
lengths.
Note: The motor cable must not be switched as
long as the inverter is providing power to the
motor. (The inverter must be on "Standby"
or "Starting Disabled")
Connection cross-section:
Size 1 … 3:
0.5 ... 6mm
2
rigid/flexible cable AWG 20-10
Size 4:
0.5 ... 16mm
2
rigid/ flexible cable AWG 20-6
Tightening torque:
1.2 ... 1.5Nm
2.7.3 Brake resistor connection (-B, +B)
Terminals +B/ -B are intended for the connection of a suitable braking resistor. The connection should be as
short as possible.
Note: The large amount of heat produced by the
brake resistor must be taken into account.
Connection cross-section:
Size 1 … 3:
0.5 ... 6mm
2
rigid/ flexible cable AWG 20-10
Size 4:
0.5 ... 16mm
2
rigid/ flexible cable AWG 20-6
Tightening torque:
1.2 ... 1.5Nm
PE
Motor