Owner's manual

SK 2x5E with "PosiCon Functionality"
34 Subject to technical amendments BU 0210 GB
Parameters
[factory setting]
Setting value / Description / Note Device Supervisor
Parameter
set
P420 [-01] Function Bus I/O In Bits
0 ... 72
[ 0 ]
The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions
(P420[01]…[03]).
[-01] = Bus I/O In Bit 0
[-02] = Bus I/O In Bit 1
[-03] = Bus I/O In Bit 2
[-04] = Bus I/O In Bit 3
[-05] = Bus I/O In Bit 4
[-06] = Bus I/O In Bit 5
[-07] = Bus I/O In Bit 6
[-08] = Bus I/O In Bit 7
[-09] = Bit 8 BUS control word
[-10] = Bit 9 BUS control word
Caution: Only the functions relevant to PosiCon are listed here.
22 = Reference point run
23 = Reference point
24 = Teach-In
25 = Quit Teach-In
55 = Bit 0 position (increment) array
56 = Bit 1 position (increment) array
57 = Bit 2 position (increment) array
58 = Bit 3 position (increment) array
61 = Reset Position
62 = Sync for position array pointer
63 = Switch off synchronous running
P481 [-01] Function Bus I/O Out Bits
0 ... 38
[ 0 ]
The Bus I/O Out Bits are perceived in the same way as for those of the digital outputs. They
can be set to the same functions (P434 / P624...629).
[-01] = Bus I/O Out Bit 0
[-02] = Bus I/O Out Bit 1
[-03] = Bus I/O Out Bit 2
[-04] = Bus I/O Out Bit 3
[-05] = Bus I/O Out Bit 4
[-06] = Bus I/O Out Bit 5
[-07] = Flag 1
[-08] = Flag 2
[-09] = Bit 10 BUS status word
[-10] = Bit 13 BUS status word
Caution: Only the functions relevant to PosiCon are listed here.
20 = Reference point
21 = Position reached
22 = Comparative position
23 = Comparative position value
24 = Position array value
25 = Comparative position reached
26 = Comparative position value Reached
Attention: The standardisation assigned to the bus IO Out bits in parameter P482 is disabled
for functions relevant to PosiCon (20 – 26, see parameterisation of function of Bus
IO Out Bits, P481 disabled).
The hysteresis assigned to the bus IO Out bits in parameter P483 is disabled for
functions relevant to PosiCon (20 – 26, see parameterisation of function of Bus IO
Out Bits, P481 disabled). With regard to the functions relevant to PosiCon, the
joint parameterisation of the hysteresis can be performed for all outputs via
parameter P625.