Owner's manual
7 Error monitoring and error messages
BU 0270 GB Subject to technical amendments 65
7.2.2 Table of possible error messages in the bus module
The following error messages concern bus-related messages, which are indicated on the EtherCAT module
SK TU4-ECT(-…))
Error number
Group Details in
P170
Fault
Text in the ParameterBox
Cause
Remedy
1000 EEPROM error
Module faulty
1010 System bus 24V missing
Check connections and supply cables
Ensure 24V voltage supply
1020 System bus timeout
Check time set in parameter (P151).
Telegram transfer is faulty.
Check external connection
Check bus protocol program process.
Check bus master.
1030 System bus OFF
Check connections and supply cables
Ensure 24V voltage supply
Check bus master.
5400 EtherCAT ASIC Error
No contact with ASIC
ASIC faulty or
EEPROM faulty
5401 EtherCAT buffer overflow
Message box (message buffer) for the module was
overwritten by a new telegram before processing
E1000
5420 EtherCAT timeout
Telegram transfer is faulty.
Check external connection.
Check bus protocol program process.
Check bus master.